![Rohde & Schwarz FSW13 User Manual Download Page 749](http://html.mh-extra.com/html/rohde-and-schwarz/fsw13/fsw13_user-manual_1477847749.webp)
Remote Commands
R&S
®
FSW
749
User Manual 1173.9411.02 ─ 19
Return values:
<RefRange>
Number of the current reference range.
Range:
1 to 30
Usage:
Query only
[SENSe:]ESPectrum<sb>:RTYPe
<Type>
This command defines the type of the power reference.
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
Parameters:
<Type>
PEAK
Measures the highest peak within the reference range.
CPOWer
Measures the channel power within the reference range (integral
bandwidth method).
*RST:
CPOWer
Manual operation:
See
11.5.6.6
Configuring the Power Classes
The following commands define the power classes for SEM measurements.
CALCulate:LIMit:ESPectrum<sb>:LIMits
...........................................................................749
CALCulate:LIMit:ESPectrum<sb>:MODE
..........................................................................750
CALCulate:LIMit:ESPectrum<sb>:VALue
..........................................................................751
CALCulate:LIMit:ESPectrum<sb>:PCLass:COUNt
.............................................................751
CALCulate:LIMit:ESPectrum<sb>:PCLass<class>[:EXCLusive]
.......................................... 752
CALCulate:LIMit:ESPectrum<sb>:PCLass<class>:LIMit[:STATe]
........................................ 752
CALCulate:LIMit:ESPectrum<sb>:PCLass<class>:MAXimum
............................................. 753
CALCulate:LIMit:ESPectrum<sb>:PCLass<class>:MINimum
.............................................. 753
CALCulate:LIMit:ESPectrum<sb>:LIMits
<Max1>,<Max2>,<Max3>
This command sets or queries up to 4 power classes in one step. You can only define
values for the number of power classes defined by
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
Configuring and Performing Measurements