Configuring a Multi-SEM Measurement
As of firmware version 1.91, and in the Spectrum application only, spectrum emissions
can be measured for multiple s ub blocks of channels (see
Multiple Sub Blocks ("Multi-SEM")"
on page 205). Up to three s ub blocks (with two
gaps) can be defined. For each s ub block, the familiar configuration settings concern-
ing ranges, limit lines and MSR can be defined in individual tabs (select the s ub block
using the <sb> suffix in the corresponding commands). In addition, settings on the s ub
blocks themselves must be configured.
Useful commands for multi-SEM measurements described elsewhere:
●
Remote commands exclusive to multi-SEM measurements
[SENSe:]ESPectrum<sb>:SBCenter
................................................................................ 732
.........................................................................................732
[SENSe:]ESPectrum<sb>:SBCenter
<Frequency>
This command defines the center frequency of the selected sub block in a Multi-SEM
measurement.
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
Return values:
<Frequency>
Frequency within the currently defined global span (see
Range:
1 to 3
*RST:
1
Manual operation:
See
[SENSe:]ESPectrum:SBCount
<S ub blocks>
This command defines the number of sub blocks in the SEM measurement.
Return values:
<Sub blocks>
Number of sub blocks in the SEM measurement.
Range:
1 to 3
*RST:
1
Manual operation:
See