Command Reference
R&S
®
CMW-KM750/-KM751
102
User Manual 1173.9670.02 ─ 05
Manual operation:
See
6.3.9 Limits (Spectrum Emission)
The following commands define limits for the spectrum emission.
..............................102
..............................102
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:EMASk:YABSolute
<EMAbsG1MLimit>, <EMAbsG30KLimit>
Defines the absolute limit line G for the spectrum emission curves, see also
Parameters:
<EMAbsG1MLimit>
Line G referenced to a 1 MHz filter
Range:
-100 dBm to 0 dBm
*RST:
-56.1 dBm
Default unit: dBm
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
<EMAbsG30KLimit> Line G referenced to a 30 kHz filter
Range:
-100 dBm to 0 dBm
*RST:
-71.3 dBm
Default unit: dBm
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.4.11
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:MEValuation:LIMit:EMASk:YRELative
<EMRelALimit>, <EMRelBLimit>, <EMRelCLimit>, <EMRelDLimit>,
<EMRelELimit>
Defines relative limits for the spectrum emission curves, see also
Parameters:
<EMRelALimit>
Limit at point A
Range:
-100 dB to 0 dB
*RST:
-49 dB
Default unit: dB
Additional parameters: OFF | ON (disables | enables the limit
check using the previous/default limit values)