Output Level Full-Scale (Peak)
..................................................................................... 45
Connector
Indicates to which audio connectors the speech codec is connected. This setting is not
configurable. It depends on the scenario and on the audio application instance.
●
"AF-1": AF 1 IN and AF 1 OUT
●
"AF-2": AF 2 IN and AF 2 OUT
●
"SPDIF-L": left channel of SPDIF IN and SPDIF OUT
●
"SPDIF-R": right channel of SPDIF IN and SPDIF OUT
●
"No Connection": there is no connection between the speech codec and the audio
connectors
Remote command:
n/a
Controlled by
Selects the controlling master application, to which the speech codec is connected.
Remote command:
ROUTe:AUDio<i>:SCENario:CATalog:MASTer?
ROUTe:AUDio<i>:SCENario:EASPeech
ROUTe:AUDio<i>:SCENario:EDSPeech
ROUTe:AUDio<i>:SCENario:MSTest
Suppress "Cell Off" Message
If the "... Signaling" softkey is selected and the cell signal is on and you press ON |
OFF, a warning can be displayed, asking whether you really want to switch off the cell
signal.
The checkbox suppresses the warning.
Remote command:
n/a
Input Level Full-Scale (Peak)
This setting configures the A/D conversion in the signal input path. It is only displayed if
the speech codec is connected to AF connectors.
The value defines the peak voltage of the analog input signal that will be converted to
the digital signal full-scale value.
Configure this setting according to the maximum voltage that you expect at the AF IN
connector, for example the voltage delivered by a connected external audio generator.
Remote command:
CONFigure:AUDio:SPEech<i>:ANALog:ILEVel
Output Level Full-Scale (Peak)
This setting configures the D/A conversion in the signal output path. It is only displayed
if the speech codec is connected to AF connectors.
The value defines the peak voltage of the analog output signal that will result from the
digital signal full-scale value.
Speech Analysis Settings