Remote Control Commands
R&S
®
AREG100A
243
User Manual 1178.7417.02 ─ 04
9.13
SOURce Subsystem
..................................................................................... 243
[:SOURce]:ROSCillator[:INTernal]:ADJust[:STATe]
.............................................................243
[:SOURce]:FREQuency[:CW|FIXed]?
...............................................................................244
[:SOURce<hw>]:FREQuency[:CW|FIXed]:RCL
................................................................. 244
[:SOURce<hw>]:AREGenerator:OBJect:ALL[:STATe]
.........................................................244
[:SOURce<hw>]:AREGenerator:OBJect<ch>:ATTenuation
................................................. 244
[:SOURce<hw>]:AREGenerator:OBJect<ch>:DOPPler
...................................................... 245
[:SOURce<hw>]:AREGenerator:OBJect<ch>:RANGe?
...................................................... 245
[:SOURce<hw>]:AREGenerator:OBJect<ch>:RCS?
.......................................................... 246
[:SOURce<hw>]:AREGenerator:OBJect<ch>[:STATe]
........................................................ 246
[:SOURce<hw>]:AREGenerator:RADar:ANTenna:CUSTom[:STATe]
.................................... 246
[:SOURce<hw>]:AREGenerator:RADar:ANTenna:REG:GAIN:RX
........................................247
[:SOURce<hw>]:AREGenerator:RADar:ANTenna:REG:GAIN:TX
........................................ 247
[:SOURce<hw>]:AREGenerator:RADar:BASE:ATTenuation
................................................248
[:SOURce<hw>]:AREGenerator:RADar:EIRP?
..................................................................248
[:SOURce<hw>]:AREGenerator:RADar:LSENsitivity
..........................................................248
[:SOURce<hw>]:AREGenerator:RADar:OTA:OFFSet
.........................................................248
[:SOURce<hw>]:AREGenerator:RADar:POWer:INDicator?
................................................ 249
[:SOURce<hw>]:AREGenerator:UNITs:RANGe
.................................................................249
[:SOURce<hw>]:AREGenerator:UNITs:RCS
..................................................................... 250
[:SOURce<hw>]:AREGenerator:UNITs:SPEed
.................................................................. 250
[:SOURce]:ROSCillator:SOURce
<Source>
Selects between internal or external reference frequency.
Parameters:
<Source>
INTernal | EXTernal
*RST:
n.a. (factory preset: INTernal)
Manual operation:
See
[:SOURce]:ROSCillator[:INTernal]:ADJust[:STATe]
<State>
Determines whether the calibrated (off) or a user-defined (on)
adjustment value
is
used for fine adjustment of the frequency.
Parameters:
<State>
0 | 1 | OFF | ON
0
Fine adjustment with the calibrated frequency value
1
User-defined adjustment value.
The instrument is no longer in the calibrated state.
The calibration value is, however, not changed. The instrument
resumes the calibrated state if you send
SOURce:ROSCillator:INTernal:ADJust:STATe 0
.
SOURce Subsystem