background image

Operation 

 

1MA236_0e

 

Rohde & Schwarz

   Remote Operation of Windows Based T&M Instruments with Android Tablets     

18

 

The tablet provides a virtual mouse and a keyboard for controlling the remote desktop 
screen.  
●  Tap "MOUSE" on the upper right to get a virtual mouse cursor and the related tap 

area. 

●  Tap "KEYBOARD" on the upper right to get a keyboard. 
 
The keyboard shows letters by default; you can switch to numbers and special charac-
ters via the "&123" key, and back to letters via the "abcd" key. 
 

4.2.2  Control Elements of the T&M Instrument Views 

In this section, the CMW is used as example. 

  Tabs 

Tabs are used to organize and distribute the content of a firmware application over 
several views. 
●  Tap a tab to change to the related view. 

  Buttons 

●  Tap a button to launch its function. 

  Softkeys, Hotkeys and Hardkeys 

The softkeys are the buttons on the right side, the hotkeys are the buttons on the bot-
tom of the T&M instrument's display. The currently active softkey determines which 
hotkeys are available.  
Hardkeys are the buttons on a panel outside of the T&M instrument's screen. 
●  Tap a softkey, hotkey or hardkey to activate it. 

  Check Boxes, Radio Buttons, List Boxes 

●  Click on a checkbox or radio button with the left mouse button to switch its state. 
●  Click on a list box with the left mouse button to open the list.  

Click on a list entry to select this entry. 

 

 

Fig. 18: List box 

Summary of Contents for AFQ100B

Page 1: ...R S ZVA R S ZVL This document describes how a Windows based R S T M instrument is remotely op erated by an AndroidTM tablet as if working on it locally Step by step procedures are pro vided for settin...

Page 2: ...ruments 8 3 1 2 2 Installation for Windows 7 T M Instruments 11 3 2 Installing the RDP Client Application on the Tablet 13 3 3 Establishing the WLAN Connection on the Tablet 13 3 4 Establishing the RD...

Page 3: ...em The same considerations are valid for the Apple iPad see application note 1MA216 Procedures and handling for Windows RT tablets are similar The R S CMW270 280 500 3 is used as example for a typical...

Page 4: ...M instrument and tablet The Remote Desktop functionality is realized by Microsoft s Remote Desktop Protocol RDP The RDP software consists of a server and a client component On Windows systems the serv...

Page 5: ...a WLAN USB adapter In this case the T M instrument sets up an own wireless network and the tablet connects to this network The devices communicate directly with each other point to point no additional...

Page 6: ...cribed in the router s manual Note It is even possible to directly access the WLAN router via tablet if both have Internet access 2 Configure the WLAN Router It is assumed that the WLAN router provide...

Page 7: ...sitivity measurements USB connectors on the rear of the T M instrument cause less interference due to the larger distance to its RX unit First Commissioning Some installation and configuration steps a...

Page 8: ...s not automatically found after plugging in the WLAN USB adapter a Files Needed window is displayed e g asking for the rt2870 sys file Here you can manually enter the correct path for driver files C w...

Page 9: ...ight click on the Wireless Network Connection entry and select Properties in the context window The Wireless Network Connection Properties window is opened Fig 5 Internet Protocol TCP IP properties 2...

Page 10: ...the Add button which opens another window 10 Configure the Wireless network properties on the Association tab Enter the desired network name e g SFC 100123 This network name will appear in the list o...

Page 11: ...Wi Fi to abstract the WLAN hardware into multiple virtual adapters In this way the Windows 7 T M instrument can establish a WLAN adhoc connection while keeping the capability to setup or access other...

Page 12: ...nto the Start menu All Pro grams Startup directory of the T M instrument 2 Right click on the file and select Edit from the context window The file is opened with Windows Notepad Fig 9 Configuring the...

Page 13: ...and tap the 2X Clients for RDP Remote Desktop App and download it The 2X Client App is installed Afterwards the 2X Client icon is shown on the Apps screen Fig 10 2X Client RDP App 3 3 Establishing the...

Page 14: ...ith USB adapter is shown with state Connected in the figure cmw500 123 Fig 12 Wi Fi networks 3 4 Establishing the RDP Connection RDP operates on the WLAN connection which has been established in the p...

Page 15: ...tion screen is displayed 4 Enter the connection information according to the figure below The hostname of the T M instrument in the Alias row optional this name provides a readable identification of t...

Page 16: ...f your T M instrument At the dialog box tap Edit The Connection screen is opened Build up of the RDP Connection 6 Tap the desired connection indicated by hostname or IP address The remote desktop conn...

Page 17: ...n 4 1 Locking the Tablet s Screen Rotation Function Proceed as follows 1 Hold the tablet in landscape format 2 Swipe one finger from the top of any screen to open the notification shade 3 Tap the AUTO...

Page 18: ...abs Tabs are used to organize and distribute the content of a firmware application over several views Tap a tab to change to the related view Buttons Tap a button to launch its function Softkeys Hotke...

Page 19: ...on an input box Then tap KEYBOARD on the upper right corner 2 a Letters Enter a letter string as required via keyboard b Numbers Switch the keyboard display mode to numbers and enter the number 3 Tap...

Page 20: ...ication by tapping softkeys and hotkeys by clicking on check boxes and list boxes Activate the keyboard for entering values in input box es 5 Start signaling Tap the LTE Signaling softkey then click o...

Page 21: ...ttom edge of the screen The Windows taskbar is shown 2 Click on Start 3 Click on Disconnect Fig 21 Disconnect via Windows taskbar If you re connect to the T M instrument after having disconnected befo...

Page 22: ...tion of R S Instruments Using Remote Desktop Connection via LAN This application note describes how to use the Remote Desktop Connection pro gram to operate R S T M instruments connected in a LAN from...

Page 23: ...4001 certified environmental management system Regional contact Europe Africa Middle East 49 89 4129 12345 customersupport rohde schwarz com North America 1 888 TEST RSA 1 888 837 8772 customer suppor...