Troubleshooting
R&S EU4200C
4.13
6174.8456.02-01
The following table shows the internal restarts triggered by recognized
failures of WD guarded parts of the device firmware and related events
logged in RX module event logs.
Source
of failure
Module
Description
Events in RX Event
Logs
Main
Processor
RX
Not controlled by WD.
MMI recognizes failure
of intermodule
communication (with
RX module) and
triggers WD restart.
107 MMI WD RESTART
Link Processor
RX
409 RX WD RESTART
Digital Signal
Processor
RX
Not controlled by WD
Partition
Management
MMI
RU
timeout
expired
Currently
booted
partitions
not equal
110 MMI PART
a b c*
439 RX PART
a b c*
Version
numbers
not equal
Part
numbers
not equal
*a
stands for currently booted partition, i.e. 1 or 2
b
stands for version number, e.g. 10.xx
c
stands for validation result, as explained in the following figure
Fig. 4.2
Events related to internal restart triggers
Note:
In case the radio was restarted on the basis of the WD RESTART
trigger and the consequent boot process was interrupted by switching the
radio off (mains failure), the original restart event (e.g. 409 RX WD
RESTART) is logged in the event log.
Summary of Contents for 6144.7800.02
Page 1: ...R S S4200 R S EU4200C VHF Compact Receiver Operating Manual Operating Manual 6174 8456 02 01 ...
Page 4: ...R S EU4200C 6174 8456 02 01 0 2 ...
Page 10: ...R S EU4200C 6174 8456 02 01 0 8 ...
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 27: ...R S EU4200C 6174 8456 02 01 0 18 ...
Page 183: ...R S EU4200C Remote Control Commands 6174 8456 02 01 6 12 ...