Remote Control Commands
R&S
®
NGP800
100
User Manual 5601.5610.02 ─ 04
0
Control beeper is deactivated.
Example:
SYSTem:BEEPer:CURRent:STATe 1
The "CC-Mode Continuous Beep" is activated, a continue beep
sound alert when the selected output channel goes into CC
mode.
SYSTem:BEEPer:PROTection:STATe
<arg0>
Sets "protection" beeper tone.
Parameters:
<mode>
1
Protection beeper is activated.
0
Protection beeper is deactivated.
Example:
SYSTem:BEEPer:PROTection:STATe 1
The "Protection Tripped Beep" is activated, a single beep alert
when a protection tripped event occurs
SYSTem:BEEPer:PROTection[:IMMediate]
Returns a single "protection" beep immediately.
Usage:
Event
SYSTem:BEEPer:WARNing:STATe
<arg0>
Enables "error/warning" beep sound.
Parameters:
<state>
1
Beep sound for "error/warning" is enabled.
0
Beep sound for "error/warning" is disabled.
SYSTem:BEEPer:WARNing[:IMMediate]
Returns a single "error/warning" beep immediately.
Usage:
Event
SYSTem:COMMunicate:SOCKet:APPLy
Apply LAN configuration settings.
Usage:
Event
System Settings Commands