Basic Safety Instructions 

1171.0000.42 - 09 

Page 3 

Operating states and operating positions 

The product may be operated only under the operating conditions and in the positions specified by the 
manufacturer, without the product's ventilation being obstructed. If the manufacturer's specifications are 
not observed, this can result in electric shock, fire and/or serious personal injury or death. Applicable local 
or national safety regulations and rules for the prevention of accidents must be observed in all work 
performed.  

1.  Unless otherwise specified, the following requirements apply to Rohde & Schwarz products:  

predefined operating position is always with the housing floor facing down, IP protection 2X, use only 
indoors, max. operating altitude 2000 m above sea level, max. transport altitude 4500 m above sea 
level. A tolerance of 

±

10 % shall apply to the nominal voltage and 

±

5 % to the nominal frequency, 

overvoltage category 2, pollution degree 2. 

2.  Do not place the product on surfaces, vehicles, cabinets or tables that for reasons of weight or stability 

are unsuitable for this purpose. Always follow the manufacturer's installation instructions when 
installing the product and fastening it to objects or structures (e.g. walls and shelves). An installation 
that is not carried out as described in the product documentation could result in personal injury or 
even death. 

3.  Do not place the product on heat-generating devices such as radiators or fan heaters. The ambient 

temperature must not exceed the maximum temperature specified in the product documentation or in 
the data sheet. Product overheating can cause electric shock, fire and/or serious personal injury or 
even death. 

Electrical safety 

If the information on electrical safety is not observed either at all or to the extent necessary, electric shock, 
fire and/or serious personal injury or death may occur. 

 

1.  Prior to switching on the product, always ensure that the nominal voltage setting on the product 

matches the nominal voltage of the mains-supply network. If a different voltage is to be set, the power 
fuse of the product may have to be changed accordingly.  

2.  In the case of products of safety class I with movable power cord and connector, operation is 

permitted only on sockets with a protective conductor contact and protective conductor. 

3.  Intentionally breaking the protective conductor either in the feed line or in the product itself is not 

permitted. Doing so can result in the danger of an electric shock from the product. If extension cords 
or connector strips are implemented, they must be checked on a regular basis to ensure that they are 
safe to use. 

4.  If there is no power switch for disconnecting the product from the mains, or if the power switch is not 

suitable for this purpose, use the plug of the connecting cable to disconnect the product from the 
mains. In such cases, always ensure that the power plug is easily reachable and accessible at all 
times. For example, if the power plug is the disconnecting device, the length of the connecting cable 
must not exceed 3 m. Functional or electronic switches are not suitable for providing disconnection 
from the AC supply network. If products without power switches are integrated into racks or systems, 
the disconnecting device must be provided at the system level. 

5.  Never use the product if the power cable is damaged. Check the power cables on a regular basis to 

ensure that they are in proper operating condition. By taking appropriate safety measures and 
carefully laying the power cable, ensure that the cable cannot be damaged and that no one can be 
hurt by, for example, tripping over the cable or suffering an electric shock.  

Summary of Contents for 4099891461454

Page 1: ...R S FPC1000 Spectrum Analyzer Getting Started Getting Started 1178 4124 02 03 YH2...

Page 2: ...9 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trad...

Page 3: ...e of the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following...

Page 4: ...ation item 7 Signal words and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers Indicates a hazardous situation which i...

Page 5: ...afety is not observed either at all or to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal...

Page 6: ...t be fuse protected in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 14 Use suitable overvoltage protection to ensure...

Page 7: ...masks and protective clothing must be worn 7 Laser products are given warning labels that are standardized according to their laser class Lasers can cause biological harm due to the properties of the...

Page 8: ...ckaging until they are ready to be used 4 Cells and batteries must not be exposed to any mechanical shocks that are stronger than permitted 5 If a cell develops a leak the fluid must not be allowed to...

Page 9: ...National waste disposal regulations must be observed 4 If handling the product releases hazardous substances or fuels that must be disposed of in a special way e g coolants or engine oils that must b...

Page 10: ...ien las informaciones de seguridad elementales as como la documentaci n del producto y entr guelas a usuarios posteriores Tener en cuenta las informaciones de seguridad sirve para evitar en lo posible...

Page 11: ...raves o incluso la muerte Indica una situaci n de peligro que si no se evita puede causar lesiones graves o incluso la muerte Indica una situaci n de peligro que si no se evita puede causar lesiones l...

Page 12: ...entaci n del producto o en la hoja de datos En caso de sobrecalentamiento del producto pueden producirse choques el ctricos incendios y o lesiones graves con posible consecuencia de muerte Seguridad e...

Page 13: ...0950 1 EN60950 1 o IEC61010 1 EN 61010 1 v lidos en cada caso 11 A menos que est permitido expresamente no retire nunca la tapa ni componentes de la carcasa mientras el producto est en servicio Esto p...

Page 14: ...manipulaci n mec nica y o t rmica o el desmontaje del producto debe tenerse en cuenta imprescindiblemente el cap tulo Eliminaci n protecci n del medio ambiente punto 1 5 Ciertos productos como p ej la...

Page 15: ...a las bater as y acumuladores o celdas pueden producirse explosiones incendios y o lesiones graves con posible consecuencia de muerte El manejo de bater as y acumuladores con electrolitos alcalinos p...

Page 16: ...sin clasificar sino que debe ser recogido por separado La eliminaci n se debe efectuar exclusivamente a trav s de un punto de recogida apropiado o del servicio de atenci n al cliente de Rohde Schwarz...

Page 17: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Page 18: ...the R S FPC1000 user manual there is a separate user manual for the R S InstrumentView software package This manual contains a description of all features of the R S InstrumentView software package T...

Page 19: ...dgment The release notes list new features improvements and known issues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbat...

Page 20: ...the first time Risk of injury and instrument damage The instrument must be used in an appropriate manner to prevent electric shock fire personal injury or damage Do not open the instrument casing Read...

Page 21: ...erating site or test setup can damage the instrument and connected devices Ensure the following operating conditions before you switch on the instrument The instrument is dry and shows no sign of cond...

Page 22: ...effects during transportation and shipment can damage the instrument Always make sure that sufficient mechanical and electrostatic protection is provided When shipping an instrument the original packa...

Page 23: ...an be installed in the 19 rack mount kit R S ZZA FPC1 order no 1328 7080 02 The installation instructions are part of the adapter kit Risk of injury if feet are folded out The feet may fold in if they...

Page 24: ...N61010 Therefore it may only be connected to an outlet that has a ground contact The AC power supply has the following characteristics Line voltage 100 V AC to 240 V AC Line frequency 50 Hz to 60 Hz 4...

Page 25: ...ly fuse Only fuses of the type 2A T IEC60127 2 V should be used 1 Disconnect the power cable 2 Open the flap covering the voltage selector using a small screwdriver or simi lar 3 Remove the cylinder l...

Page 26: ...ment Tour The R S FPC1000 has various connectors on the front and rear panel 3 1 Front Panel 1 5 3 2 4 6 Figure 3 1 Front panel of the R S FPC1000 1 USB ports type A 2 Headphone jack 3 Softkeys 4 Func...

Page 27: ...FPC1000 Typically you connect the DUT with a cable and an appropriate connector for example a male N connector The frequency range of the RF input is specified in the datasheet The attenuation range i...

Page 28: ...onnect devices like memory sticks Function keys and alphanumeric keypad The function keys provide access to the measurement settings and functions The alphanumeric keypad allows you to enter alphanume...

Page 29: ...nstrument The main power switch has the following states Position 1 The instrument is supplied with power Position 0 The instrument is disconnected from the power supply Trigger input external referen...

Page 30: ...dBm LAN The LAN interface allows you to connect the R S FPC1000 to a local network for remote control printouts or data transfer The assignment of the RJ 45 connector supports twisted pair category 5...

Reviews: