Remote control commands
R&S
®
NRX
230
User Manual 1178.5566.02 ─ 09
.................................................................................231
TRIGger<Measurement>[:CHANnel<Channel>]:DELay:AUTO
............................................231
TRIGger<undef>:ALL:DELay[:VALue]
.............................................................................. 232
TRIGger<Measurement>[:CHANnel<Channel>]:DELay[:VALue]
......................................... 232
...........................................................................................232
TRIGger<Measurement>[:CHANnel<Channel>]:DTIMe
......................................................232
TRIGger<Measurement>[:CHANnel<Channel>]:EXTernal<Port>:IMPedance
........................................................................................233
TRIGger<Measurement>[:CHANnel<Channel>]:HOLDoff
...................................................233
................................................................................... 233
TRIGger<Measurement>[:CHANnel<Channel>]:HYSTeresis
.............................................. 233
TRIGger<Measurement>[:CHANnel<Channel>]:JITTer:METHod
.........................................234
............................................................................................234
TRIGger<Measurement>[:CHANnel<Channel>]:LEVel
.......................................................234
...........................................................................................235
......................................................................................235
TRIGger<Measurement>[:CHANnel<Channel>]:SENDer:PORT
..........................................235
TRIGger<Measurement>[:CHANnel<Channel>]:SENDer[:STATe]
....................................... 236
..........................................................................................236
TRIGger<Measurement>[:CHANnel<Channel>]:SLOPe
.....................................................236
........................................................................................237
TRIGger<Measurement>[:CHANnel<Channel>]:SOURce
...................................................237
TRIGger<Measurement>[:CHANnel<Channel>]:SYNChronize:PORT
..................................237
TRIGger<undef>:ALL:SYNChronize[:STATe]
.....................................................................238
TRIGger<Measurement>[:CHANnel<Channel>]:SYNChronize[:STATe]
................................238
TRIGger<undef>:ALL[:IMMediate]
................................................................................... 238
TRIGger<Measurement>[:IMMediate]
.............................................................................. 238
TRIGger<undef>:ALL:ATRigger[:STATe]
<stat>
TRIGger<Measurement>[:CHANnel<Channel>]:ATRigger[:STATe]
<stat>
Controls the automatic trigger function. If enabled, an artificial trigger is generated if the
delay time has elapsed after the measurement start and no trigger event has occurred.
The auto delay is set using
TRIGger<Measurement>[:CHANnel<Channel>]:
The command is not fully R&S
NRP2 compatible. If port
1 is assigned to measure-
ment
1 and so on, the command works. If port
1 is assigned to measurement
2, for
example, enable the R&S
NRP2 emulation using
"NRP2"
.
Suffix:
<Measurement>
.
1 to 8
Measurement
<Channel>
1 to 2
1 = primary sensor, 2 = secondary sensor
Parameters:
<stat>
ON | OFF
*RST:
ON
Measurement settings and results