Roger SL2000H Manual Download Page 6

Security Lock SL2000H v1.0 EN Rev.C.doc   

2011-11-16 

 

 

 

Page 6 of 11

 

 
 

[*][Old INSTALLER Code][#][New INSTALLER Code] [#] 

This command erases the current INSTALLER code and program a new one. If command 
is successfully accomplished the unit generates three series of two beeps (** ** **) 

[*] [Old MASTER Code] [#][Old MASTER Code] [#] 

This command erases the current MASTER code and program a new one. If command is 
successfully accomplished the unit generates three series of two beeps (** ** **). 

[#]  

Normally pressing [#] is used to mark the end of the code but when pressed separately 
for a time longer the 0.5s it triggers Door Bell indication. 

Programming The USER Codes 

The SL2000 enables programming of up to 55 different USER codes. The USER codes can 
be managed (added/deleted/changed) only in the Installer Programming mode (to enter 
Installer Programming mode press: [INSTALLER Code]+[#]). Once in the Installer 
Programming mode you have following commands: 

[0] [1] [#] [code] [# ]

   ; Programming of the USER code no. 1 

[0] [2] [#] [code] [#]

 

; Programming of the USER code no. 2 

… etc. 
… etc. 
… etc. 

[5] [5] [#] [code] [#]

 

; Programming of the USER code no. 55 

[0] [0] [#]

   

 

; Delete all USER codes 

[9] [9] [#][code][#]

 

; Deletes the code entered in square brackets 

[#]

 

 

 

 

; Exit from the Installer Programming mode 

When the SL2000 accepts the new USER code it generates two series of two beeps (** 
**). Any attempt to program the USER code which already exists in the memory or to 
program it with a wrong length then will cause the programming error signaled by a long 
acoustic beep.  

Configuring the SL2000 — Memory Reset 

In order to configure the SL2000 you must perform the Memory Reset procedure and 
then enroll sequentially 10 digits (C1,C2..C10) which will configure the unit for the 
individual installation. After the Memory Reset the entire code lock memory is erased 
(including all codes) and initialized with default (factory)

 

settings.  

In order to perform Memory Reset do the following steps: 

 

Turn off the power supply 

 

Put the jumper on JP1 contacts 

 

Turn on the power supply 

 

Wait till the moment when SL2000 will generate three series of two beeps (**  **  
**) - this signal indicates that unit has erased memory and restored default 
configuration parameters 

 

Remove jumper from JP1 contacts 

Meaning of the configuration parameters: C1-C10 
C1C2:

 Specifies the time delay from a moment when USER code is entered till moment 

when Door Lock output will be triggered. It can be programmed from 00 to 99s (default: 
04). 

Note: Whenever you re-program MASTER or INSTALLER code remember that new code 

programmed into a unit must have the same length as the old one. 

Summary of Contents for SL2000H

Page 1: ...Roger Sp j Electronic Code Lock SL2000H v1 0 Document version Rev C ...

Page 2: ... be configured to operate in one of two modes Door Lock or Status The OUT2 has fixed function and is always assigned to signal Door Bell and Door Alarm states The REL1 output offers one switched NO NC contact rated 1 5A 30V AC DC The OUT1 and OUT2 lines are open collector transistor lines which normally remain in high resistance state however when triggered they short to supply minus The OUT1 2 tr...

Page 3: ...lock works in Disarmed mode The Status Output can be physically assigned to either Relay or OUT1 physical output for details see JP3 JP4 JP5 and JP6 settings The Status output can be used for rearming of an alarm zone or to control any other device or system which requires the ON OFF method of control This kind of operation is often called bistable or latch mode Either REL1 or OUT1 can be configur...

Page 4: ...yellow shorting this input with supply minus lights up LED SYSTEM The LED SYSTEM can be use to any arbitrary selected purpose required by the installer e g to indicate actual status of the alarm system or any other state Special options Option 1 Timed Lock Out If this option is enabled the Sl2000 disables the keypad for 60 seconds after three attempts of entry of the incorrect code After this time...

Page 5: ...00 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code The INSTALLER code is required to enter the Installer Programming mode it can be 4 10 digits long USER Codes These codes are used solely to trigger the Door Lock momentary output Each time a valid USER code is entered the SL2000 starts counting C1C2 time delay and then activates Door Lock output for time defined by the C...

Page 6: ...aller Programming mode When the SL2000 accepts the new USER code it generates two series of two beeps Any attempt to program the USER code which already exists in the memory or to program it with a wrong length then will cause the programming error signaled by a long acoustic beep Configuring the SL2000 Memory Reset In order to configure the SL2000 you must perform the Memory Reset procedure and t...

Page 7: ... of the MASTER and INSTALLER codes enter 0 3 default 1 0 Both codes are 4 digits long 1 Both codes are 6 digits long 2 Both codes are 8 digits long 3 Both codes are 10 digits long If an illegal operation occur during Memory Reset the device will signal an error long beep and will return to the beginning of the programming so you can start to enter the C1 C10 digits once again The Memory Reset proc...

Page 8: ...vertical piece of supporting structure The SL2000H can be installed either indoor or outdoor location Assure that the surface beneath of the controller s rear panel is flat and smooth Disconnect power supply before making any electrical connections Once installed and electrically connected the unit has to be properly programmed When forgotten MASTER and INSTALLER codes can be restored to their def...

Page 9: ...Security Lock SL2000H v1 0 EN Rev C doc 2011 11 16 Page 9 of 11 ...

Page 10: ...REL1 NO REL1 NC REL1 output 1 5A 24V DC AC Technical Specification Parameter Value Supply 10 15 VDC Current consumption Avg 25 mA 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class Class IV outdoor general temp 25 C 60 C relative humidity 0 95 Dimensions 160 X 90 X 45 mm Weight SL2000H 1300g Approvals CE Ordering Information Ite...

Page 11: ... crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and electronic equipment Recycling helps to reduce the consumption o...

Reviews: