Roger PR411DR-SET Installation Manual Download Page 4

Installation guide for PR4xxDR-SETv2 Rev.A.doc

 

2017-02-02 

 

 

4/5 

 

 

Fig. 1 Schematic view of PR4xxDR-SET enclosure 

4.

 

O

RDERING INFORMATION

 

Table. 2 Ordering information 

PR411DR-SET 

Access control set containing PR411DR-BRD module access controller, mains 

power supply module and metal enclosure 

PR402DR-SET 

Access control set containing PR402DR-BRD module access controller, mains 
power supply module and metal enclosure 

PR411DR 

Access controller in 35mm DIN rail enclosure 

PR402DR 

Access controller in 35mm DIN rail enclosure 

PR411DR-BRD 

Access controller module adapted to installation on DIN 35mm rail 

PR402DR-BRD 

Access controller module adapted to installation on DIN 35mm rail 

5.

 

P

RODUCT HISTORY

 

Table 3. Product history 

Product version 

Released 

Description 

PR4xxDR-SET v2.0 

01/2017 

First commercial version of the product 

 

Summary of Contents for PR411DR-SET

Page 1: ...2DR SET Hardware version 2 0 Document version Rev A 2017 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Page 2: ...other terminals working in one of popular data transmission formats like Wiegand or Magstripe Connection method is given in Installation Guides of PR411DR and PR402DR controllers Benefits related to access control sets Complete solution The kit contains all apart from readers devices needed to build fully functional access control point Esthetical metal enclosure Quick and easy installation by mea...

Page 3: ... While choosing a place for installation please make sure that ventilating holes placed at the back side of the enclosure are not covered Note Prior to starting installation and maintenance works it is necessary to ensure that 230VAC power supply is disconnected Any works inside the enclosure should be done with disconnected 230VAC voltage It is forbidden to use power supply unit without proper an...

Page 4: ...trol set containing PR402DR BRD module access controller mains power supply module and metal enclosure PR411DR Access controller in 35mm DIN rail enclosure PR402DR Access controller in 35mm DIN rail enclosure PR411DR BRD Access controller module adapted to installation on DIN 35mm rail PR402DR BRD Access controller module adapted to installation on DIN 35mm rail 5 PRODUCT HISTORY Table 3 Product h...

Page 5: ...ints of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Go...