background image

MCX16-AP Operating manual.doc 

  

2018-11-29 

 

3/12 

 

necessary to activate it by re-initializing the MC16 controller with connected expander (

Run device discovery

 

command in VISO software). 

Note: Any modification of license file will corrupt the file. The expander cannot operate without valid license. 

Power supply and backup battery 

MCX16  module  is  designed  for  power  supply  from  230VAC/18VAC/40VA  transformer  and  then  it  offers 
12VDC  power  outputs  (AUX,  TML)  for  external  devices.  Optionally  the  expander  can  be  supplied  from 
12VDC  or  24VDC  but  in  case  of  12VDC  the  backup  battery  cannot be  directly  connected  to the  expander 
thus the emergency power supply must be provided by external PSU. 

Note: MCX16 module cannot be started using only power supply from backup battery. 

 

Fig. 2 MCX16 supply from 18VAC 
 

 

Fig. 3 MCX16 supply from 12VDC or 24VDC 

IN1..IN8 inputs 

The  expander  offers  8  inputs  which  can  be  configured  as  NO  or  NC.  The  configuration  of  input  electrical 
parameters is done within low level configuration by means of RogerVDM software. Inputs are assigned with 
functions using VISO management software. 

OUT1-OUT6 outputs 

The  expander  offers  six  open  collector  type  transistor  outputs  OUT1-OUT6.  Output  polarity  can  be 
configured  as  normal  or  reversed.  Output  with  normal  polarity  represents  high  impedance  in  normal  state 
and  is  shorted  to  ground  when  triggered.  Output  with  reversed  polarity  operates  with  inverted  logic.  It  is 
shorted  to  ground  in  normal  state  and  represents  high  impedance  when  triggered.  The  configuration  of 

Summary of Contents for MCX16-AP

Page 1: ...Roger Access Control System MCX16 AP I O expander with APERIO interface Operating manual Product version 1 1 Firmware version 1 0 2 x Document version Rev A...

Page 2: ...puts NO NC 6 transistor outputs 12V 1 0A 2 relay outputs NO NC 30V 1 5A DC AC Power outputs 13 8V 1 0A and 13 8V 0 2A 18VAC or 12VDC power supply Battery charging with 0 3A current Protection against...

Page 3: ...ided by external PSU Note MCX16 module cannot be started using only power supply from backup battery Fig 2 MCX16 supply from 18VAC Fig 3 MCX16 supply from 12VDC or 24VDC IN1 IN8 inputs The expander of...

Page 4: ...to controller The expander is operated as an extension of MC16 access controller After addressing in 100 115 range the expander is connected to RS485 communication bus of controller where MCT readers...

Page 5: ...MCX16 AP Operating manual doc 2018 11 29 5 12 Fig 5 Connection diagram for expander supplied from controller s kit Fig 6 Connection diagram for expander supplied from controller...

Page 6: ...with standard U UTP cat 5 cable The MC16 controller via MC16 AP expander s can control up to 16 locks doors depending on its license MC16 controller MCX16 AP expander and AH 40 hubs can be operated in...

Page 7: ...ional configuration with VISO management software Configuration parameters In the table below the configuration parameters of MCX16 AP expander are presented All settings are programmed with RogerVDM...

Page 8: ...mal or reversed Range 0 No 1 Yes Default value 0 No Power supply settings Battery test period min Parameter defines time between successive battery tests Range 10 1440 Default value 10 AC lost delay m...

Page 9: ...card to computer Copy the new firmware frg to the memory card and rename it as FW BUF Insert the memory card into expander socket Restore power supply and expander will automatically start the firmwa...

Page 10: ...Ground B2 not used Table 3 LED indicators LED Steady light Pulsing light AC AC supply available DC DC supply at TML AUX terminals available LED1 Established connection with hub 1 LED2 Established con...

Page 11: ...Power supply outputs Two power outputs 12VDC 0 2A TML and 12VDC 1A AUX rated RS485 port Two RS485 communication ports Ethernet port 10BASE T 10 100Mb communication port Distances Max 1200 m between c...

Page 12: ...electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste c...