Roger Access Control System 

MCX16-AP I/O expander with APERIO interface 

Operating manual 

Product version: 1.1 

Firmware version: 1.0.2.x 

Document version: Rev. A 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for MCX16-AP

Page 1: ...Roger Access Control System MCX16 AP I O expander with APERIO interface Operating manual Product version 1 1 Firmware version 1 0 2 x Document version Rev A...

Page 2: ...puts NO NC 6 transistor outputs 12V 1 0A 2 relay outputs NO NC 30V 1 5A DC AC Power outputs 13 8V 1 0A and 13 8V 0 2A 18VAC or 12VDC power supply Battery charging with 0 3A current Protection against...

Page 3: ...ided by external PSU Note MCX16 module cannot be started using only power supply from backup battery Fig 2 MCX16 supply from 18VAC Fig 3 MCX16 supply from 12VDC or 24VDC IN1 IN8 inputs The expander of...

Page 4: ...to controller The expander is operated as an extension of MC16 access controller After addressing in 100 115 range the expander is connected to RS485 communication bus of controller where MCT readers...

Page 5: ...MCX16 AP Operating manual doc 2018 11 29 5 12 Fig 5 Connection diagram for expander supplied from controller s kit Fig 6 Connection diagram for expander supplied from controller...

Page 6: ...with standard U UTP cat 5 cable The MC16 controller via MC16 AP expander s can control up to 16 locks doors depending on its license MC16 controller MCX16 AP expander and AH 40 hubs can be operated in...

Page 7: ...ional configuration with VISO management software Configuration parameters In the table below the configuration parameters of MCX16 AP expander are presented All settings are programmed with RogerVDM...

Page 8: ...mal or reversed Range 0 No 1 Yes Default value 0 No Power supply settings Battery test period min Parameter defines time between successive battery tests Range 10 1440 Default value 10 AC lost delay m...

Page 9: ...card to computer Copy the new firmware frg to the memory card and rename it as FW BUF Insert the memory card into expander socket Restore power supply and expander will automatically start the firmwa...

Page 10: ...Ground B2 not used Table 3 LED indicators LED Steady light Pulsing light AC AC supply available DC DC supply at TML AUX terminals available LED1 Established connection with hub 1 LED2 Established con...

Page 11: ...Power supply outputs Two power outputs 12VDC 0 2A TML and 12VDC 1A AUX rated RS485 port Two RS485 communication ports Ethernet port 10BASE T 10 100Mb communication port Distances Max 1200 m between c...

Page 12: ...electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste c...