Roger Access Control System 

MCX102-BRD Operating Manual 

Product version: 1.0 

Firmware version: 1.0.4 or newer 

Document version: Rev. A 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for MCX102-BRD

Page 1: ...Roger Access Control System MCX102 BRD Operating Manual Product version 1 0 Firmware version 1 0 4 or newer Document version Rev A...

Page 2: ...pology can be freely arranged as star tree or any combination of them except for loop The matching resistors terminators connected at the ends of transmitting lines are not required In most cases comm...

Page 3: ...tion RogerVDM Function are assigned to outputs within high level configuration VISO Multiple functions with different priorities can be assigned to the same output at the same time 2 INSTALLATION Each...

Page 4: ...plied from the same PSU then GND terminals of both devices must be connected with any wire 3 OPERATION SCENARIOS In typical scenario of operation MCX102 BRD expander is used to control single door by...

Page 5: ...ating Manual 04 12 2020 5 12 Fig 3 Scenario of operation with MCX102 BRD expanders Note The enclosure ME 2 D offers enough space and PSU to install up to three MCX102 BRD expanders in order to control...

Page 6: ...MCX102 BRD Operating Manual 04 12 2020 6 12 Fig 4 Typical door control with PRT series readers...

Page 7: ...RogerVDM program select MCX v1 x device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically d...

Page 8: ...er Range Yes No Default value Yes Min PIN length Parameter defines the minimal number of digits for PIN entered with keypad When set to 0 then PINs are disabled Range 0 8 Default value 4 Max PIN lengt...

Page 9: ...I BUZZER LED SYSTEM LED OPEN LED STATUS comment Parameter defines any text or comment which corresponds to the object It is later displayed in VISO program Wiegand terminal 1 Terminal enabled When opt...

Page 10: ...restores factory default settings including ID 100 software address Expander memory reset procedure 1 Remove all connections from A B CLK and DTA terminals 2 Place jumper on 64 contacts and restart d...

Page 11: ...isolated NO NC contact 30V 1 5A max load Transistor output Single OUT1 transistor output max load 15VDC 150mA Distances Up to 1200 m between controller and expander RS485 Up to 150m between expander a...

Page 12: ...ectric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste con...