![Roger LRT-1 Operating Manual Download Page 11](http://html.mh-extra.com/html/roger/lrt-1/lrt-1_operating-manual_1477176011.webp)
LRT-1 Operating Manual.doc
2018-09-06
11/13
Fig. 8 Connection of LRT-1 reader to PRxx1 or PRxx2 access controller
Installation
1.
LRT-1 reader must be installed on vertical structure (wall, pole) in a place which is free from strong
electromagnetic interferences and possibly far from metal objects.
2.
Configure MCI-1 interface prior to connection.
3.
The address of MCI-1 interface can be configured manually for both RACS 4 and RACS 5 operating
modes without connection of MCI-1 to computer.
4.
Full configuration of MCI-1 interface can be done only with RogerVDM program ad it requires
connection of RUD-1 interface.
5.
MCI-1 interface must be installed indoors, preferably in the same metal enclosure as access controller.
6.
MCI-1 interface can be mounted on flat surface with two screws or on DIN rail with included holder.
7.
All electrical connections must be made with switched off power supply.
8.
Start and verify the operation of devices when electrical connections are finished.