AUTOMATIC TELEPHONE ALARM DIALER 

DIAL 1602M 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

OPERATION AND INSTALLATION INSTRUCTION MANUAL 

 
 

 

 
 

Summary of Contents for DIAL 1602M

Page 1: ...AUTOMATIC TELEPHONE ALARM DIALER DIAL 1602M OPERATION AND INSTALLATION INSTRUCTION MANUAL ...

Page 2: ...aler is originally equipped with a 3V 120mAh battery which guarantees keeping up the memory for minimum 60 days in case of a power supply loss The memory stores the alarm telephone numbers alarm messages history of events and dialer configuration parameters A power supply loss results only in resetting the time and date A lack or low battery voltage lower than 2 7V at a power supply loss results i...

Page 3: ...the power supply voltage is higher than 9 5V the dialer will display the Roger DIAL1602 message and test the RAM memory If the dialer programming has been lost the First start of dialer message is displayed and then DIALER PROGRAMMING LOST ENTER DEFAULT CODE Then you should press the key and after message Enter code is displayed you should enter the default installer code i e 1234 end the code ent...

Page 4: ...e duration of PGM output activation from the moment a loud alarm is switched on min 000s max 255s Pause between alarms 000min In case of a double message dialer it specifies the duration of alarm line blocking from the moment the notification action was stopped which was initiated in this line It is shared by both alarm inputs In case of a single message dialer both alarm lines are blocked for the...

Page 5: ... the alarm to the right from the caption Ready Alarm types AG loud alarm activates the PGM output AC silent alarm does not activate the PGM output AN duress alarm silent alarm in the line A DURESS ALARM DURESS ALARM DURESS ALARM DURESS ALARM You can initiate the duress alarm in the Blocking or Ready mode by entering the duress code digit Regardless the line A programming as silent or loud or the d...

Page 6: ...ROGER s c DIAL 1602 v1 0 25 11 1999 5 ...

Page 7: ...ROGER s c DIAL 1602 v1 0 25 11 1999 6 Schematic of changing the DIAL1602 dialer operating modes NOTE Pause after the duress alarm equals 0 minutes INSTAL CODE Installer code USR CODE User Code ...