CPR32-SE-BRD v3.0 User Manual

 

2020-10-08 

 

 

10/15 

 

 

Fig. 7 Main window of PR Master software 

 

Fig. 8 CPR32-SE-BRD options in PR Master 

It is possible to configure some additional options by clicking 

CPR32-SE

 in the main window of 

PR  Master  software  which  results  in  opening  the  window  shown  in  fig.  8  including  summary  of 
CPR32-SE-BRD setup and top menu with following options and commands: 

Menu: Settings->Options 

In  the  window  opened  by  means  of  this  option,  the  administrator  can  activate/deactivate  power 
supply tests and internal tests of CPR32-SE-BRD unit as well as switch the CPR off and on. 

Menu: Settings->Inputs/Outputs 

In the window opened by means of this option it is possible to assign functions to CPR32-SE-BRD 
inputs and outputs. Additionally in case of inputs the administrator can define their NO/NC type and 

in  case  of  outputs  their  normal/inverted  type.  All  input  functions  can  be  divided  into  ON/OFF 
monitored and ON monitored. In case of ON/OFF monitored input functions, CPR32-SE-BRD detects 

the moment of input activation and deactivation. In case of ON monitored input functions, CPR32-
SE-BRD  detects  only  their  activation,  thus  it  is  not  relevant  how  long  the  input  is  activated  and 
when it is deactivated as only the activation triggers certain actions within the system. The list of 

available functions is shown in table 4 and table 5. 

Summary of Contents for CPR32-SE-BRD

Page 1: ...version 3 0 5133 or newer Hardware version 3 0 Document version Rev B 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at th...

Page 2: ...3 3 Power supply 6 3 4 Communication with CPR 8 3 5 Input and output lines 8 3 5 1 Inputs 8 3 5 2 Relay outputs 8 3 5 3 General purpose outputs 8 3 6 Installation guidelines 9 4 Configuration 9 4 1 C...

Page 3: ...erns PRxx1 series controllers The network controller is equipped with RS485 port which is used for direct communication with access controllers and for communication with computer PR Master software u...

Page 4: ...IN8 input line P2 Power supply for CPR IO1 IO1 output line COM REL1 relay common terminal IO2 IO2 output line NC REL1 relay output NC IN1 IN1 input line NO REL1 relay output NO IN2 IN2 input line CLK...

Page 5: ...CPR32 SE BRD v3 0 User Manual 2020 10 08 5 15 Fig 2 Typical connection diagram for CPR32 SE BRD v3 0 network controller...

Page 6: ...roller is designed for power supply from 230VAC 18VAC transformer with minimal power output 25VA but it can also be supplied with 12VDC The connection of power supply is shown in fig 4 and fig 5 If CP...

Page 7: ...CPR32 SE BRD v3 0 User Manual 2020 10 08 7 15 Fig 4 CPR32 SE BRD v3 0 and PR402DR PR411DR controllers supplied with 18VAC Fig 5 CPR32 SE BRD v3 0 and PRxx1 PRxx2 series controllers supplied with 12VDC...

Page 8: ...istors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twisted pair etc b...

Page 9: ...n bus including connected access controllers CPR32 SE BRD network controller and communication interface e g UT 2USB the installer can proceed with installation and configuration of PR Master software...

Page 10: ...CPR off and on Menu Settings Inputs Outputs In the window opened by means of this option it is possible to assign functions to CPR32 SE BRD inputs and outputs Additionally in case of inputs the admin...

Page 11: ...ed at all controllers doors within subsystem network 12 Clear all alarms in subsystem ON monitored When the input is activated then all alarms in CPR32 SE BRD and controllers within particular subsyst...

Page 12: ...es controllers within the subsystem network 73 Alarm in CPR The output is activated for 3 minutes if Tamper Alarm or Power supply alarm is raised The function 67 operates as a sum of 81 and 82 functio...

Page 13: ...ut is activated for 3 minutes when the event memory buffer is filled in 75 90 Low battery 3 min The output remains activated for 3 minutes if charge level of backup battery connected to CPR32 SE BRD u...

Page 14: ...d with CPR32 SE BRD network controller connected to PC through such serial interfaces as UT 2USB RUD 1 or UT 4 with virtual serial port then CPR is erroneously detected by Windows as Microsoft Serial...

Page 15: ...have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling...