![ROEL Alcar H51 Installation Manual Download Page 4](http://html1.mh-extra.com/html/roel/alcar-h51/alcar-h51_installation-manual_1476961004.webp)
Installation Manual
Alcar
®
H51
4
C
HAPTER
III: G
ENERAL
F
EATURES
1. Arming/disarming by remote controls (confirmation by siren chirps and flashing)
2. Arming/disarming by remote controls (confirmation by flashing only)
3. Passive arming (programmable) / Warning at passive arming
4. Arming with silent alarm
(no siren, programmable)
5. Two steps disarming
6. Protection against accidental disarming
(auto-arming)
7. Doors protection
8. Trunk and hood protection, apart from the door input
9. Pre-warning for weak shocks, alarm for strong shocks or repeated weak shocks
10. External sensors connection possibility (microwave, simple or dual and/or ultrasonic)
11. Car find
12. Panic
13. Reverse car moving warning
(programmable)
14. Warning for door open
(programmable)
15. Warning when approaching the car
(optional, programmable)
16. Warning when arming with the lights turned on
17. Engine killing
18. Option for deactivating any sensor by remote control
19. Defective sensors bypassing when arming
20. Separate power supply for each sensor input
21. Low consumption
(disconnecting the bypassed sensors power supply)
22. Remote alarm notify
(optionally, by pager)
23. Non-volatile memory for system parameters and remote controls
24. System state keeping when disconnecting and reconnecting the power supply
25. Learning/clearing remote controls procedure
26. System parameters programming procedure
27. Learnt remote controls number notification
28. Anti-car-jacking
procedure (programmable)
29. Anti-scanning / Anti-grabbing
30. Service mode / Emergency disarming by valet switch
31. Central door lock module incorporated
32. Remote controlled doors lock/unlock and/or when switching ON/OFF the engine (optionally,
programmable)
33. Electric windows closing when arming the system (optionally)
34. Trunk release by remote control (optionally)
35. Events Log on the state LED
(alarm memory indications)
36. Bypassed defective sensors indicated on the state LED
37. Back-up battery siren
(optionally)
21
Notes:
a) If the system is armed with silent alarm function (no siren), the alarm state will be notified by
pager and flashing lights or only by pager, according to the value of parameter 9
(see 5.2., system
parameters);
b) Any alarm state can be stopped by pressing shortly (0.5s) the button 1 or 2, without disarming
the system. For disarming the system when the alarm is in progress, press button 1 twice (once to
stop the alarm and second time to disarm the system).
5.18 C
OMFORT
F
UNCTION
The Comfort function is available for some newer models of cars. At these cars, when twisting the
key the doors will lock. If maintaining the key twisted for more than 5s then the windows will roll up.
The Comfort function provides when arming a longer trigger (10s) on the lock doors output, no
matter of parameter 1 value.
Caution!
Do not run this wire directly to the door lock actuator, but to the command wires existing on the car!
For details please call the manufacturer!
5.19 D
OOR
CONTACTS
DELAY
,
WHEN
ARMING
This function is only used for the cars which maintain ON the dome lamp, a certain time, after the
last door is closed. In this case, the parameter 11 Door contacts delay, when arming will be
programmed actively. Then, the state of the door pin switches is only tested after the delay time
estabilished by parameter 12.
If after delay time, the alarm system detects at least a door opened, it notifies by 3 opto-acoustic
signals and bypasses the respective input. If afterwards all the doors will be closed, the respective
input becomes actively again. The signal for the door inputs will be taken from the (+) terminal of the
dome lamp.
C
HAPTER
VI: T
ESTING
/A
DJUSTMENTS
6.1 R
EAL
CONDITIONS
TESTING
1)
Stop the engine, close the doors, the hood and the trunk. Arm and disarm the system with and
without acoustical confirmation like. The state LEDwill indicate as follows:
-
blinking slow
system is armed;
- off
system is disarmed;
-
on
system is in alarm;
-
blinking fast
system is within the 30s after disarm command, when it is waiting for a
door to be opened (see 5.9).
- system is within 30s after the engine was turned off and the last door was closed and it is
counting the time for passive arming
(see 5.10).
- short blinks
after disarming and closing the last door the system indicates the alarm memory or
the faulty inputs type; while in programming mode the system indicates the parameters values.
2)
Arm the system and bypass manually by remote control the sensors according to 5.5.5. Check
the fact that power supply of the bypassed sensor was disabled while armed (sensors LED is off
and the alarm system does not respond when the sensor is tested).
3)
Arm the system and simulate various situations so, after 20s from arming
(at the end of the