8.3 Ballast Weight Calculation
Hallen Wind: 125N / m
2
Safety Factor: 1.5
The following table shows the ballast in KG per tile width. The ballast should be distributed evenly.
W
H
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
2
9
17
25
34
42
50
58
67
75
83
91
100
108
116
124
3
19
38
56
75
93
112
131
149
168
186
205
223
242
261
279
4
34
67 100
133
166 199
232
265
298
331
364
397
430
463
496
5
52
104 155
207
259 310
362
413
465
517
568
620
671
723
775
6
75
149 223
298
372 446
521
595
669
744
818
892
967
1041
1115
7
102
203 304
405
506 607
709
810
911
1012
1113
1214
1315
1417
1518
8
133
265 397
529
661 793
925
1057
1189
1322
1454
1586
1718
1850
1982
W
H
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
2
133
141
149
157
166
174
182
190
199
207
215
223
232
240
248
3
298
316
335
353
372
391
409
428
446
465
484
502
521
539
558
4
529
562
595
628
661
694
727
760
793
826
859
892
925
958
991
5
826
878
929
981 1033 1084 1136 1187 1239 1291 1342 1394 1445 1497 1549
6 1189 1264 1338 1412 1487 1561 1635 1710 1784 1858 1933 2007 2081 2156 2230
7 1619 1720 1821 1922 2023 2125 2226 2327 2428 2529 2630 2731 2833 2934 3035
8 2114 2246 2378 2511 2643 2775 2907 3039 3171 3303 3435 3567 3700 3832 3964
Note:
H refers to DM2.6 tiles height, W refers to DM2.6 tiles width in the above table. (Unit: piece)
Formula:
Base Stabilizer Length (1m) x Ballast Weight (N) = Half of the tile height (m) x Tile Area (
㎡
) x
125N/
㎡
x Safety Factor (1.5)