Problem
Cause
Solution
The machine
doesn’t start.
The power supply cable is
damaged or not properly con-
nected.
No voltage in the power outlet.
Start switch is damaged.
Press the plug firmly in the power
outlet. Check the power supply
cable.
Have the power outlet checked.
Have the switch replaced.
Water doesn’t flow
at the blade but the
pump is running.
The sprayers are clogged.
The water level in the water bin
is not sufficient. The pump is not
totally submerged.
Water valve is closed.
Clean the sprayers.
Fill the water bin with clean
water until the pump is totally
submerged.
Open the valve.
Motor isn’t running
smoothly.
Water may have seeped
through inside the motor.
Capacitor is damaged.
Damaged motor bearing.
Unplug the power cable and
consult your local dealer.
Pump isn’t running. The impeller or suction filter of
the pump is damaged.
No proper connection of the
power cable.
Replace damaged parts.
Have the connection checked.
Cutting out of align-
ment.
Machine is not leveled out.
Unstable working surface.
Improper or glazed diamond
blade.
Loosen the screws for the legs.
Pick up the machine a little bit on
one end. Let the machine down
again and tighten screws. Per-
form the same procedure on the
other end. The machine should
now be leveled out.
Make sure the machine is placed
on a leveled surface.
Replace or dress the diamond
blade.
12. DECLARATION OF
CONFORMITY
We declare under our sole responsibility
that this product is in conformity with the
following standards or standardization
documents.
98/392/EEC, 91/368/EEC,
93/44/EEC, 93/68/EEC,
89/336/EEC, 92/31/EEC,
73/23/EEC
09
Subject to change without notice.
R.G.W. van den Boogaart
General Manager
Zevenbergen, December 2009