E10160-200722
FOP
Page 3
advantage of this model is his ability to be protected against all forms of corrosion as there is
no metallic part on the sensor.
1.2 CALIBRATION
All piezometers are individually calibrated before shipment. Each piezometer is tested over
its working pressure range and they are tested in temperature (except FOP micro-PZ and
FOP-PZ).
A calibration data sheet supplied with each gauge, lists the following:
Serial number
Gauge factor and/or calibration factors
Working pressure (in bar or psi)
Temperature at time of factory calibration
Barometric pressure at time of factory calibration
Fiber optic cable type and length.
1.3 FOP SPECIFICATIONS
PERFORMANCE
Models:
FOP, FOP-C, FOP-F, FOP-P
Pressure range:
200, 350, 500, 750, 1000, 1500, 2000,
3000, 5000, 7000 kPa
(1)
25, 50, 75, 100, 150, 250, 300, 500, 750,
1000 psi
(1)
Resolution:
0.025% Full Scale
Accuracy:
+/-0.25% Full Scale
EMI / RMI susceptibility:
Intrinsic immunity
Proof pressure:
1.5x of rated pressure
(1) Other ranges available upon request.