© Copyright 2014 Easthill Group, Inc. Instruction part #30462Q Rev. 7/14
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.544.5118 >> email: [email protected]
PDF version of this manual is available online >> eastwood.com/30462manual
The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA
US and Canada: 800.345.1178 Outside US: 610.718.8335 Fax: 610.323.6268 eastwood.com
TROUBLESHOOTING
• No LED illumination.
– Check 120 VAC input plug connection.
• Red “Reverse Polarity” LED Illuminated =
DISCONNECT IMMEDIATELY.
This indicates
an abnormal condition such as crossed polarity, an internally shorted battery or pinched cable.
Do not reconnect until the source of the warning is found.
• No Ammeter Reading/Battery slow to charge or will not charge.
– Unplug Battery Charger and check terminal condition and connections. Remove and clean
battery terminals and cable ends.
– Check Battery Charger Cable Clamp connections. Wiggle the clamp while holding onto terminal
to allow clamp teeth to “bite” into terminal.
– Check that the correct Charge Rate switch position has been selected for the battery
being
charged.
– Check that the correct Battery Type switch position has been selected for the battery
being
charged.
– Check that the Charge/Engine Start switch position is in the Charge position.
– Battery is excessively cold. Charge rate will increase signifi cantly above 32°F.
– Ensure that suffi cient time has been allowed for charging – refer to Charging Time section
of these instructions.
– Make sure the battery voltage is at least 2.5 volts. Battery may be fully discharged and
will not accept charging.
– Battery may be sulfated.
– Battery may be expired and internally shorted.