Install the Factory-supplied DC Power Connector Assembly

For 6300B-BMAx and 6300B-BMBx Box PCs, and 6300T-BAx1 Box Thin Clients

This connector assembly provides strain relief for the DC power wires by reducing their movement. To assemble and attach the connector assembly, perform the following steps.

1.

Remove the DC terminal block from the computer chassis.

2.

Open the power connector assembly kit that ships with the computer (A).

3.

Insert the cable tie through the slots of the appropriate connector half (B).

4.

Strip the end of each DC power wire to the length in 

Figure 2

.

5.

Insert each stripped end into the DC terminal block as shown in 

Figure 2

.

Figure 2 - DC Terminal Block Connection Specifications

6.

Tighten the screws on top of the terminal block to secure the DC power wires to the torque value in 

Figure 2

.

7.

Slide the connector half with the attached tie onto the end of the DC terminal block (C).

8.

Tighten the cable tie so it is snug against the terminal wires. 

9.

Use cutting pliers to cut the excess part of the cable tie (D).

10. Install the white label supplied with the kit (E).

11.

Align and install the other connector clamp half to complete the assembly (F).

12. Reconnect the DC terminal block with the connector assembly to the computer chassis. 

Torque the DC terminal block flange screws to the values in 

Figure 2

.

13. Proceed to 

Connect DC Power on page 6

.

IMPORTANT

The DC terminal block in the photos is only for illustrative purposes. Your DC terminal block can differ in size, shape, and color to 

what is shown in the photos.

The white label can be used for identification or other information.

When installed correctly, both tabs of the clamp half lock into place.

Item

Description

6300B-BMAx and 

6300T-BAx1 Models

6300B-BMBx Models

1

DC+ (24V DC nominal) recommended power wire size

(1)

(1)

DC power wires must be of stranded copper and certified for at least 85 °C operation.

1.5 mm

2

 (16 AWG)

2.5 mm

2

 (14 AWG)

2

DC- (0V DC) recommended power wire size

(1)

3

Stripped wire length

7 mm (0.275)

4

Torque range to secure DC power wires

0.22...0.25 N•m 

(0.16...0.18 ft•lb)

0.5...0.6 N•m 

(0.37...0.4 ft•lb)

5

Torque value to reinstall DC terminal block to computer

0.3 N•m (0.22 ft•lb)

DC Terminal Block for 

Cat. Nos. 6300-BMAx 

and 6300T-BAx1 Models

DC Terminal Block for 

Cat. No. 6300-BMBx Models

D

A

B

C

E

F

Summary of Contents for Allen-Bradley VersaView 6300B

Page 1: ...ing to the Connect Peripherals section The picture for 6300B BMFx and 6300B DRFx models The digital input output I O item to the picture and table The USB cable length stipulation 4 Changed the heading from Connect DC Power to Connect DC Power Wiring 4 Added the subheading For 6300B BMAx and 6300B BMBx Box PCs and 6300T BAx1 Box Thin Clients to the Install the DC Connector Assembly section 5 Added...

Page 2: ... at the bottom as shown in Figure 1 on page 3 Mount the box PC or box thin client so there is at least 20 mm 0 8 in of clearance on each side for the circulation necessary for cooling Required Tools and Hardware for Installation The following tools are needed for the mounting bracket installations A drill and 4 mm drill bit 2 Phillips screwdriver Four M4x20 stainless steel screws customer supplied...

Page 3: ...0 75 230 9 06 19 0 75 6 0 24 4 x Ø 4 1 8 25 0 98 25 0 98 100 3 97 150 5 9 5 5 0 22 100 3 97 150 5 9 256 5 10 1 268 10 6 Front View Vertical Upright Position Side View 6300B BMAx Box PCs and 6300T BAx1 Box Thin Clients 6300B BMBx Box PCs 221 8 7 6300B BMFx Box PCs 47 1 85 4 5 0 18 127 25 5 01 140 5 51 20 0 79 100 3 94 8 25 0 32 77 3 03 100 3 94 20 0 79 4 x Ø 4 5 0 18 Front View Vertical Upright Pos...

Page 4: ...wer Wiring Follow these steps to connect the box PC or box thin client to a DC power source Install the Ground Wire 1 Turn off the main power switch or breaker 2 Remove the supplied nut eyelet terminal and washers from the ground screw 3 For earth ground fasten a 2 5 mm2 14 AWG or larger external wire to the eyelet terminal Use a ground wire with an insulation color that is approved by local inspe...

Page 5: ...es 9 Use cutting pliers to cut the excess part of the cable tie D 10 Install the white label supplied with the kit E 11 Align and install the other connector clamp half to complete the assembly F 12 Reconnect the DC terminal block with the connector assembly to the computer chassis Torque the DC terminal block flange screws to the values in Figure 2 13 Proceed to Connect DC Power on page 6 IMPORTA...

Page 6: ...ally starts the computer after it is plugged into a power source For VersaView 6300B box PCs with a Microsoft Windows operating system OS you must read and accept an End User Setup procedure Do not disconnect power from the system until after the Windows Setup procedure is completed If power is disconnected during this procedure it can result in a corrupted system image Table 1 LEDs and Buttons on...

Page 7: ...ate and time 5 Watchdog LED Green The watchdog is working Red The watchdog timer has expired 6 PLC status LED 2 7 BUS status LED 2 8 Power on reset button Turns the computer on or off 9 System reset button Forces an internal reset as if power was lost temporarily and then returned IMPORTANT Use this button only if there are no better options like keyboard or mouse commands System reset can cause d...

Page 8: ...on its website at rok auto pec Your comments help us serve your documentation needs better If you have any suggestions on how to improve our content complete the form at rok auto docfeedback For technical support visit rok auto support Rockwell Otomasyon Ticaret A Ş Kar Plaza İş Merkezi E Blok Kat 6 34752 İçerenkÖy İstanbul Tel 90 216 5698400 EEE YÖnetmeliğine Uygundur This computer contains a sea...

Reviews: