Rockwell Automation Publication 6300B-IN001C-EN-P - February 2021
5
VersaView 6300B Box PCs and 6300T Box Thin Clients Installation Instructions
Install the Factory-supplied DC Power Connector Assembly
For 6300B-BMAx and 6300B-BMBx Box PCs, and 6300T-BAx1 Box Thin Clients
This connector assembly provides strain relief for the DC power wires by reducing their movement. To assemble and attach the connector assembly, perform the following steps.
1.
Remove the DC terminal block from the computer chassis.
2.
Open the power connector assembly kit that ships with the computer (A).
3.
Insert the cable tie through the slots of the appropriate connector half (B).
4.
Strip the end of each DC power wire to the length in
5.
Insert each stripped end into the DC terminal block as shown in
.
Figure 2 - DC Terminal Block Connection Specifications
6.
Tighten the screws on top of the terminal block to secure the DC power wires to the torque value in
.
7.
Slide the connector half with the attached tie onto the end of the DC terminal block (C).
8.
Tighten the cable tie so it is snug against the terminal wires.
9.
Use cutting pliers to cut the excess part of the cable tie (D).
10. Install the white label supplied with the kit (E).
11.
Align and install the other connector clamp half to complete the assembly (F).
12. Reconnect the DC terminal block with the connector assembly to the computer chassis.
Torque the DC terminal block flange screws to the values in
.
13. Proceed to
.
IMPORTANT
The DC terminal block in the photos is only for illustrative purposes. Your DC terminal block can differ in size, shape, and color to
what is shown in the photos.
The white label can be used for identification or other information.
When installed correctly, both tabs of the clamp half lock into place.
Item
Description
6300B-BMAx and
6300T-BAx1 Models
6300B-BMBx Models
1
DC+ (24V DC nominal) recommended power wire size
(1)
(1)
DC power wires must be of stranded copper and certified for at least 85 °C operation.
1.5 mm
2
(16 AWG)
2.5 mm
2
(14 AWG)
2
DC- (0V DC) recommended power wire size
(1)
3
Stripped wire length
7 mm (0.275)
4
Torque range to secure DC power wires
0.22...0.25 N•m
(0.16...0.18 ft•lb)
0.5...0.6 N•m
(0.37...0.4 ft•lb)
5
Torque value to reinstall DC terminal block to computer
0.3 N•m (0.22 ft•lb)
DC Terminal Block for
Cat. Nos. 6300-BMAx
and 6300T-BAx1 Models
DC Terminal Block for
Cat. No. 6300-BMBx Models
D
A
B
C
E
F