SMC™ Flex Quick Start
Power Wiring
Refer to the product nameplate or the SMC Flex User Manual for device specific information.
Control Terminals
SMC Rating
[A]
Lug Kit
Cat. No.
Wire Strip
Length
Conductor
Range
Max. No. Lugs/Pole
Tightening Torque
Line Side
Load Side
Wire - Lug
Lug - Busbar
5…85
—
18…20 mm
2.5…85 mm
2
(#14…3/0 AWG)
—
—
11.3 N•m
(100 lb•in)
—
108…135
199-LF1
18…20 mm
16…120 mm
2
(#6…250 MCM)
1
1
31 N•m
(275 lb•in)
23 N•m
(200 lb•in)
201…251
199-LF1
18…20 mm
16…120 mm
2
(#6…250 MCM)
2
2
31 N•m
(275 lb•in)
23 N•m
(200 lb•in)
317…480
199-LG1
18…25 mm
25…240 mm
2
(#4…500 MCM)
2
2
42 N•m
(375 lb•in)
28 N•m
(250 lb•in)
625…780
100-DL630
32 mm/64 mm
70…240 mm
2
(2/0…500 MCM)
2
2
45 N•m
(400 lb•in)
68 N•m
(600 lb•in)
970
100-DL860
26 mm/48 mm
120…240 mm
2
(4/0…500 MCM)
1
1
45 N•m
(400 lb•in)
68 N•m
(600 lb•in)
1250
100-DL630
32 mm/64 mm
70…240 mm
2
(2/0…500 MCM)
1
1
45 N•m
(400 lb•in)
68 N•m
(600 lb•in)
100-DL860
26 mm/48 mm
120…240 mm
2
(4/0…500 MCM)
1
1
Terminal
Description
Terminal
Description
Footnotes
11
➂➃
Control Power Input (+)
23
➀
PTC Input
➀
Do not connect any additional loads to these
terminals. These “parasitic” loads may cause
incorrect operation.
➁
When set for External Bypass mode, the SMC
Flex can be used to control a properly sized
external contactor and overload once the motor
reaches full speed. The SMC-Flex overload
functionality is disabled in this mode.
➂
RC Snubbers are required on inductive type
loads connected to auxiliary contacts.
➃
Control power on units rated 625…1250 A is
pre-wired internally, from terminal block CP1.
12
➂➃
Control Power Common
24
➀
PTC Input
13
➀
Controller Enable Input
25
Tachometer Input
14
Ground
26
Tachometer Input
15
➀➂
Option Input #2
27
➀
Ground Fault Transformer Input
16
➀➂
Option Input #1
28
➀
Ground Fault Transformer Input
17
➀➂
Start Input
29
➁➂
Aux Contact #2
18
➀➂
Stop Input
30
➁➂
Aux Contact #2
19
➁➂
Aux Contact #1
31
➁➂
Aux Contact #3
20
➁➂
Aux Contact #1
32
➁➂
Aux Contact #3
21
Not Used
33
➁➂
Aux Contact #4
22
Not Used
34
➁➂
Aux Contact #4
23 24 25 26 27 28
29 30 31 32 33 34
11 12 13 14 15 16
17 18 19 20 21 22