Important:
When this function is enabled, the following conditions
must be met:
•
A proper minimum value must be set for Sleep Level
(182).
•
At least one of the following must be programmed in
Digital Inx Sel (361 to 366): Enable,
Stop=CF, Run, Run Forward, Run Reverse.
Sleep-Wake Operation
The basic operation of this function is to start (wake) the drive when
an analog signal is greater than or equal to a user-specified wake
level and stop the drive when an analog signal is less than or equal
to a user-specified sleep level.
Assuming all drive permissive conditions are met, the drive will start
when Sleep-Wake Mode (178) is enabled (= Direct) and the
absolute value of the Sleep-Wake Ref (179) is greater than the
programmed Wake Level (180) for longer than the programmed
Wake Time (181).
The drive will stop when the absolute value of the Sleep-Wake Ref
(179) is less than the programmed Sleep Level (182) for longer than
the programmed Sleep Time (183).
While the drive is measuring the time above Wake Level (180), it will
indicate a "Waking" alarm. If Sleep-Wake Ref (179) goes above
Sleep Level (182) or below Wake Level (180) the corresponding
timer is reset (Wake timer and Sleep timer, respectively).
While the drive is "awake", all other active stop commands will be
honored immediately (i.e. no Sleep timer). However, after a stop is
commanded, a new start command while Sleep-Wake Ref (179) is
above Sleep Level (182) will be required to reset the sleep-wake
controller. Similarly, while the drive is “asleep”, the selected logic
control source can still start the drive. In this case, the sleep-wake
controller must also be reset (stop, then restart with analog input
above sleep level).
Table 11.3 – Sleep-Wake Mode
Start Requirements When Sleep-Wake Mode is Enabled
Configured
Digital
inputs
At Power Up
After Fault Reset
After Stop
Stop-CF
(OIM or TB)
Clear Faults
(TB or VS Utilities)
OIM, TB, or
Network Stop
Stop
Stop Closed
Wake Signal
Stop Closed
Wake Signal
Start/Run Signal
Stop Closed
Wake Signal
Stop Closed
Wake Signal
Start/Run Signal
Enable
Enable Closed
Wake Signal
Enable Closed
Wake Signal
Start/Run Signal
Enable Closed
Wake Signal
Enable Closed
Wake Signal
Start/Run Signal
Run
Run Forward
Run Reverse
Wake Signal
Run Closed
Wake Signal
Run Signal
Wake Signal
Run Closed
Wake Signal
Run Signal
StockCheck.com
Downloaded from StockCheck.com
Summary of Contents for Reliance electric 6SB401 Series
Page 10: ...VIII SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 14: ...1 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 48: ...Mounting the Drive 3 12 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 86: ...Installing Control Wiring 7 14 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 102: ...10 8 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 232: ...Technical Specifications A 8 S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 248: ...B 16 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 256: ...C 8 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 258: ...D 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 260: ...E 2 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 266: ...F 6 SP600 AC Drive User Manual S t o c k C h e c k c o m Downloaded from StockCheck com ...
Page 273: ...S t o c k C h e c k c o m Downloaded from StockCheck com ...