Kinetix VP Electric Cylinders
Catalog Number Explanation
Catalog numbers consist of various characters, each of which identifies a specific version or
option for that component. Use this catalog explanation to understand the configuration of your
actuator.
Motor Mounting
(1)
A = Axial (in-line)
B = Top (parallel)
D = Left (parallel)
E = Right (parallel)
Holding Brake
2 = No Brake
4 = 24V DC Brake
P = 18-bit absolute multi-turn digital encoder (Hiperface DSL protocol)
Q = 23-bit absolute multi-turn digital encoder (Hiperface DSL protocol) SIL 2 (PLd) rated,
12-bit secondary safety channel
W = 18-bit absolute multi-turn digital encoder (Hiperface DSL protocol) SIL 2 (PLd) rated,
9-bit secondary safety channel
Mechanical Drive/Screw Lead, Motor Type
B = 3.0 mm/rev (0.118 in./rev)
C = 5.0 mm/rev (0.197 in./rev)
E = 10.0 mm/rev (0.394 in./rev)
F = 12.7 mm/rev (0.50 in./rev)
H = 20.0 mm/rev (0.787 in./rev)
Rod Stroke Length
100 = 100 mm (3.94 in.)
200 = 200 mm (7.87 in.)
300 = 300 mm (11.81 in.)
400 = 400 mm (15.75 in.)
600 = 600 mm (23.62 in.)
800 = 800 mm (27.56 in.)
Actuator Frame Size
1 = 32
2 = 40
3 = 63
Voltage Class
A = 200V
B = 400V
X = Actuator cylinder replacement part
(refer to Actuator Cylinders on page
for examples on how to order)
Actuator Type
AR = Actuator Rod
Bulletin Number
VP = Kinetix® VP
(1)
This field does not apply to actuator cylinder replacement parts.
VP AR -
xx
xxx
x
-
x x
x
MP AR -
xx
xxxxxx
Accessory Item Number
Accessory Type
NA = Axial (In-line) Mounting Accessory
NP = Parallel Mounting Accessory
NE = Rod-end Accessory
Actuator Type
AR = Actuator Rod
Bulletin Number
MP = MP-Series™ and Kinetix VP Actuator Accessory