3–5
Access Procedures
Publication 1336 IMPACT-6.8 – November, 2002
Component
Torque N-m
Torque in.-lb
Fastener Application
Thermostat
Thermostat to heat sink
14
1.6
Bus Capacitor Holder
Holder to Bus Capacitors
26
2.9
Capacitor Bus Bar Assembly
Assembly to Bus Capacitors
50
5.6
Power Module Gate Interface Board
Board to Power Modules
18
2.0
Power Module Bus Bar
Bus Bar to Power Modules
90
10
Power Module
Module to heat sink
SCR and Diode
SCR or Diode to heat sink
Refer to Note 1
SCR and Diode Assembly
Clamp nuts
240
27
SCR and Diode Assembly
Heat sink to Back-up Plate
75
8.5
SCR and Diode Assembly
Back-up Plate to Inverter Assembly
75
8.5
SCR and Diode Assembly
U-shaped Bus Bar to Inverter Assembly
240
27
SCR and Diode Assembly
Square Bus Bar Plate to Inverter Assembly
240
27
SCR and Diode Assembly
HV Guard to SCR and Diode Assembly
26
2.9
Transitional Bus Bar Assembly
Assembly to Power Module Bus Bar Assembly
80
9.0
Bus Fuse F1 – F3
Fuse to Transitional Bus Bar Assembly
240
27
DC Bus Inductor L1
Inductor to chassis
75
8.5
Bus Bar Cable Adaptor
Adaptor to Transitional Bus Bar Assembly and
DC Bus Inductor, right side of Motor Flex Bus
75
8.5
Converter Bus and Motor Bus Bars
All connections
240
27
Wires (PE)
Wires to Ground Stud
175
20
Wire (TE)
Wire on Control Board Mounting Plate
26
2.9
Wires
Wires to TB1
16
1.8
Wires
Wires to TB2
7
0.8
Wires
Wires to TB3
8 – 10
0.9 – 1.1
Power Cables
Cables to terminals
240
27
Control, Gate Driver, Common Bus Precharge
Board Mounting Plates
Plates to chassis
26
2.9
Heat Sink Guard
Guard to chassis
18
2.0
T-Bar Mounting Bolt
T-Bar to Main Frame
240
27
Capacitor Mounting Bolt
Capacitor Bank Assembly to Main Frame
240
27
Inverter Housing Assembly Lock-Down Bolt
Inverter Housing Assembly to Main Frame
240
27
Wheel Chock Fasteners
Wheel Chocks to tracks
75
8.5
Ground Cable Bolts
Ground Cables from both assemblies to Main Frame
75
8.5
Converter Bay Fuses (F1, F1A, etc.)
Fuse to bus
445
50
Converter Diodes
Converter Diode to heat sink
50
5.6
Converter Bay Thermal Switches
Thermal Switch to heat sink
16
1.8
Converter Bus Bars
L-shaped Bus Bar to Diode and bus bar interconnections
90
10
Converter Fans
Fan to heat sink
12
1.4
1
Refer to the gauge on the clamp, which indicates pounds of force. The reading should be 400 lbs.
Summary of Contents for Allen-Bradley IMPACT 1336 Series
Page 1: ...Troubleshooting Manual 1336 IMPACT Adjustable Frequency AC Drive 519 597 kW 700 800 HP ...
Page 174: ...7 14 Schematics Publication 1336 IMPACT 6 8 November 2002 This Page Intentionally Left Blank ...
Page 175: ...Notes Publication 1336 IMPACT 6 8 November 2002 ...
Page 176: ...N 2 Publication 1336 IMPACT 6 8 November 2002 ...
Page 177: ...N 3 Publication 1336 IMPACT 6 8 November 2002 ...
Page 178: ...N 4 Publication 1336 IMPACT 6 8 November 2002 ...
Page 179: ...N 5 Publication 1336 IMPACT 6 8 November 2002 ...
Page 180: ...N 6 Publication 1336 IMPACT 6 8 November 2002 ...
Page 181: ...N 7 Publication 1336 IMPACT 6 8 November 2002 ...
Page 182: ...N 8 Publication 1336 IMPACT 6 8 November 2002 ...
Page 183: ...N 9 Publication 1336 IMPACT 6 8 November 2002 ...
Page 184: ...N 10 Publication 1336 IMPACT 6 8 November 2002 ...
Page 185: ...N 11 Publication 1336 IMPACT 6 8 November 2002 ...
Page 186: ...N 12 Publication 1336 IMPACT 6 8 November 2002 ...
Page 187: ...N 13 Publication 1336 IMPACT 6 8 November 2002 ...
Page 188: ...N 14 Publication 1336 IMPACT 6 8 November 2002 ...
Page 194: ...Index I 6 Publication 1336 IMPACT 6 8 November 2002 This Page Intentionally Left Blank ...
Page 195: ......