Rockwell Automation Publication 440L-IN012A-EN-P - November 2017
15
GuardShield Type 4 and GuardShield Remote Teach
Table 28 - GuardShield Light Curtain Standard and GuardShield Light
Curtain with ArmorBlock Guard I/O Module Connectivity
The transmitter is not expected to be connected to the ArmorBlock
Guard I/O module.
Table 29 - Standard GuardShield Light Curtain Receiver Connector
Table 30 - GuardShield Light Curtain Receiver Connector for
ArmorBlock Guard I/O Module Connectivity
Table 31 - Interconnect Patchcords for Cascading GuardShield Light
Curtain
Figure 32 - Example of Patchcord for Interconnecting Cascading
GuardShield Light Curtain
Transmitter Connection
Face View of Female DC Micro
Color
Pin No.
Signal
Transmitter
Brown
1
+24V DC
White
2
No Connection
Blue
3
0V DC
Black
4
Machine Test Signal
Receiver Connection
Face View of Female DC Micro
Color
Pin No.
Signal
Receiver
White
1
Auxiliary Output
Brown
2
+24V DC
Green
3
Ground
Yellow
4
EDM
Gray
5
OSSD 1
Pink
6
OSSD 2
Blue
7
0V DC
Red
8
Start/Restart
Top View
Color
Pin No.
Signal
Receiver
Brown
1
+24V
White
2
OSSD 2
Blue
3
0V
Black
4
OSSD 1
Gray
5
NC
Cat. No.
Description
Transmitter Patchcord
889D-F4HLDM-0M3
4-pin M12 patchcord, 12 inches
889D-F4HLDM-1
4-pin M12 patchcord, 1 meter
889D-F4HLDM-2
4-pin M12 patchcord, 2 meters
Receiver Patchcords
889D-F8ABDM-0M3
8-pin M12 patchcord, 12 inches
889D-F8ABDM-1
8-pin M12 patchcord, 1 meter
889D-F8ABDM-2
8-pin M12 patchcord, 2 meters
Shorting Plug (Required for cascading GuardShield light curtain if last pair in cascade system or
standalone pair.)
Receiver
898D-81CU-DM
Termination plug 8-pin M12 quick-disconnect
1
4
3
2
2
1
5
8
7
6
4
3
1
3
2
5
4