4
Rockwell Automation Publication 6181X-IN002D-EN-P - February 2020
Industrial Computers for Hazardous Locations
Hazardous Locations
This equipment is suitable for these location categories.
IMPORTANT
6181X computers can only be used in non-hazardous locations in any Eurasian Conformity
region.
Computer
Model
Cat. Nos.
Region
Rating
Temperature Range
Non-display
6181X-
00N2SW71DC,
6181X-
00N2SWX1DC
United States
Class IN Division 2, Groups A, B, C, D T4
-20 °C < T
a
< 70 °C
(-4 °F < T
a
< 158 °F)
Class I Zone 2, IIC, T4
Canada
Class I Division 2, Groups A, B, C, D T4
Class I Zone 2, IIC, T4
Europe (ATEX)
II 3 G, Ex ec IIC T4 Gc,
DEMKO 19 ATEX 2274 X
Global/IECEx
Ex ec IIC T4 Gc, IECEx UL 19.0091 X
INMETRO
Ex ec IIC T4 Gc, UL-BR 19.1305 X
Display
(12 in.)
6181X-
12P2SWX1DC
United States
Class I Division 2, Groups A, B, C, D T4
Class II Division 2, Groups F, G T6
Class III Division 1 T6
-20 °C < T
a
< 55 °C
(-4 °F < T
a
< 131 °F)
(display side)
-20 °C < T
a
< 70 °C
(-4 °F < T
a
< 158 °F)
(backside)
Class I Zone 2, IIC, T4
Class II Zone 22, IIIB, T70 °C
Canada
Class I Division 2, Groups A, B, C, D T4
Class II Division 2, Groups F, G T6
Class III Division 1 T6
Class I Zone 2, IIC, T4
Class II Zone 22, IIIB, T70 °C
Europe (ATEX)
II 3 GD, Ex ec IIC T4 Gc IP66,
Ex tc IIIC T70 °C Dc IP66,
DEMKO 19 ATEX 2274 X
Global/IECEx
Ex ec IIC T4 Gc IP66,
Ex tc IIIC T70 °C Dc IP66,
IECEx UL 19.0091 X
INMETRO
Ex ec IIC T4 Gc IP66,
Ex tc IIIC T70 °C Dc IP66,
UL-BR 19.1305 X
Display
(12 in.)
6181X-
12A2SW71DC,
6181X-
12A2SWX1DC
United States
Class I Division 2, Groups A, B, C, D T4
-20 °C < T
a
< 55 °C
(-4 °F < T
a
< 131 °F)
(display side)
-20 °C < T
a
< 70 °C
(-4 °F < T
a
< 158 °F)
(backside)
Class I Zone 2, IIC, T4
Canada
Class I Division 2, Groups A, B, C, D T4
Class I Zone 2, IIC, T4
Europe (ATEX)
II 3 GD, Ex nA nC IIC T4 Gc IP66,
Ex tc IIIC T135 °C Dc IP66, DEMKO
17 ATEX 1851 X
Global/IECEx
Ex nA nC IIC T4 Gc IP66,
Ex tc IIIC T135 °C Dc IP66,
IECEx UL 17.0024 X