Mounting Clearances
When selecting an installation site for the computers, be sure to allow adequate clearance on
the sides and rear of the computer for proper ventilation, cable connection, and hardware
access. Sufficient airflow throughout the system unit is required to maintain proper cooling.
Clearance should be enough to allow convenient installation or removal of peripheral
components, such as the CompactFlash card.
IMPORTANT
Use adequate ventilation or other cooling methods to maintain the product temperature
at its specified rating.
Because of self-heating, do not operate the computer in an enclosure using the minimum
clearances unless adequate ventilation or other cooling methods are used to lower the
temperature within the enclosure.
Item
Description
Value
1
Top
50 mm (2 in.)
2
Back
50 mm (2 in.)
3
Left (for airflow)
50 mm (2 in.)
4
Right (for airflow and drive access)
127 mm (5 in.)
5
Bottom (for I/O port access and ventilation)
102 mm (4 in.)