Rockwell Automation Allen-Bradley 46DFA-L2LBT1-A2 Installation Instructions Manual Download Page 2

2

Rockwell Automation Publication 46DFA-IN001A-EN-P - January 2019

PHOTOSWITCH DIN  Rail Fiber Optic Amplifier

Fiber-optic Cable Installation

Figure 3 - Installation Into Amplifier Unit

Figure 4 - Coaxial-reflection Type Fiber-optic Cable

Attach the multi-core fiber-optic cable to the receiver side and the 

single-core fiber cable to the transmitter side.

Figure 5 - Thin Fiber-optic Cable

Basic Settings and Operation

Figure 6 - Basic Settings

Teach Procedure

Hold down SET during normal operation, as shown in 

Figure 7

to start 

the teaching operation. Five types of teaching are available by operation 

of the SET button.

Figure 7 - Normal Operation/Sensitivity Teach Flow

Figure 8 - Two-point Teach

This procedure sets the threshold as the average of the received light 

levels at the two positions for which teaching was performed. For 

example, the received light for the first point is 4000 and the received 

light for the second point is 2000. The threshold is automatically set to 

3000.

Figure 9 - Position/Precision Teach

This procedure sets the threshold for the received light levels at the 

position to be detected. For example, the received light level during 

position teach is 1000 and the threshold is automatically set to 1000.

Figure 10 - Window Teach Mode

1. Flip down the lock lever.

2. Insert the fiber-optic cable unit until it 

stops.

3. After inserting the fiber-optic 

cable unit, flip up the lock lever 

and secure the cable.

Flip the lever up and 

secure the cable unit.

Multi-core fiber cable

Single-core fiber cable

When using a thin fiber-optic cable unit, use the 

adapter that is provided with the fiber-optic cable unit.

L

D

Operating Indicator

(Orange)

Setting/Teach 

Indicator (Orange)

[UP/DOWN] button
• To adjust threshold
• To select settings

L: Light Operate

D: Dark Operate

indicator (Orange)

Received Light

Level (Red)

Threshold Level

(Green)

[SETTING/TEACH] button
• To start teaching
• To confirm a selected 

setting

Normal

Operation

To cancel the 

teach process, 

press UP or 

DOWN once.

When the teach operation is properly

completed, the set threshold is displayed.

Ready for the 

second-point 

teach.

Hold down SET 

within 3 seconds to

complete the second-

point teach.

Hold down SET for 3

seconds or more and

the position  teach

is complete.

When the teach operation is properly

completed, the set threshold is displayed.

UP

DOWN

SET

SET

Hold down SET 8 

seconds or more to 

enter the full auto 

teach.

Hold down SET within 3

seconds to enter the 

two-point teach. 

Teach for the 

first 

point is complete.

Hold down SET for 3 

seconds or more and 

the maximum sensitiv-

ity teach is complete.

Hold down SET for 8

seconds or more to

to enter the teach

window mode.

Object 

Present

SET

SET

Object

Present

Release

the button.

Release the button

to complete the

two-point teach.

First step

Second step

In less than 3 seconds

Hold and maintain for less than 3 seconds.

Object

 not Present

SET

SET

Object

Present

Release

the button.

Release the button

to complete the

positioning teaching.

Positioning

Release in less than 3 seconds.

Hold and maintain for more 

than 3 seconds.

In less than

3 seconds

First Step

Second step

Object

Present

Object

Present

Release

the button.

Hold down for

more than 8 seconds.

Release the button

to complete the

window mode teach.

Set two thresholds (high/low) for the 2 teaching points.
Example:

 

 

Received light level for the 1st point: 4000 (high)

the 2nd point: 2000 (low)

 

 

Received light level for 

Thresholds are set to 4000 and 2000.

Summary of Contents for Allen-Bradley 46DFA-L2LBT1-A2

Page 1: ...using pin 2 when connected using IO Link enables continuous sensor monitoring without impact on response time needs Fast response speeds of 50 s 500 s 4 ms and 32 ms allows operators easy adaptation o...

Page 2: ...cable unit L D Operating Indicator Orange Setting Teach Indicator Orange UP DOWN button To adjust threshold To select settings L Light Operate D Dark Operate indicator Orange Received Light Level Red...

Page 3: ...Use the bu on to specify between 1 and 9999 ms in increments of 1ms The ini al se ng is 1 ms source level adjustment The light source intensity can be adjusted both automa cally and manually NOTE The...

Page 4: ...al Opera on ECO mode Used to reduce power consump on Approx 15 seconds a er the se ng the 7 segment indica on turns OFF Pressng any bu on turns the display on and turns it o again a er 15 seconds Bu o...

Page 5: ...Service Func on Command or Index 60 Strandard I O Return to the Se ng mode go to Received light level indica on and select Standard indica on Then teaching can be conducted as described in 5 2 Teachi...

Page 6: ...s are operating in close proximity To enable this function the Bulletin 46DFA amplifier must be installed side by side and as close as possible in the DIN rail To be sure there s a reliable crosstalk...

Page 7: ...0 mA 30V DC class 2 or less residual voltage 2V or less Output modes Selectable Light Operate L O or Dark Operate D O OutputTimers ON delay Off delay ON OFF delay Resettable One shot Timer off Delay t...

Page 8: ...base Articles How toVideos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate the phone number for your country h...

Reviews: