Installation Instructions
Original Instructions
PHOTOSWITCH DIN Rail Fiber Optic Amplifier
Catalog Numbers 46DFA-L2LBT1-A2, 46DFA-L2LBT1-F4, 46DFA-L2LBT1-Y4
Description
Bulletin 46DFA PHOTOSWITCH® DIN rail fiber-optic amplifier is a
dual display that is designed for the detection of objects with the use of a
standard 2.2 mm (0.09 in.) diameter fiber-optic cable. These sensors are
ideal for assembly and packaging applications where you detect objects
in limited spaces or applications that require high speeds. Additional
sensing flexibility can be achieved when used with the wide variety of
fiber-optic tips.
Bulletin 43G glass fiber-optic cables compatible with this amplifier are
ideal for use in high temperature applications. For continuous
movement and high-flex applications, we recommend the use of the
Bulletin 43P small aperture plastic fiber cables.
Features
• Two high-visibility displays provide configuration and operation
feedback that makes the sensor easy to set up, operate, and
maintain.
• ECO (economy) display mode reduces amplifier power
consumption by 25%.
• Teachable LED intensity provides added flexibility in
applications where there’s a need to detect clear or transparent
objects.
• Fast-response output using pin 2 when connected using
IO-Link enables continuous sensor monitoring without impact
on response time needs.
• Fast response speeds of 50 µs, 500 µs, 4 ms, and 32 ms allows
operators easy adaptation of the sensor response time to their
application needs.
• Built-in totalizer feature allows operator to trigger the sensor
output once a certain count value has been reached.
• Cross-talk protection enables operation of sensors in close
proximity without an impact on performance.
• Selectable PNP and NPN output using push button simplifies
inventory.
• Embedded IO-Link 1.1 Communication protocol that is offered
in all standard modes.
• IP40 rated enclosure.
Sensor Installation
Figure 1 - DIN Rail and Dedicated Mounting Bracket
Figure 2 - Amplifier Case Cover
Topic
Page
Fiber-optic Cable Installation
1. DIN rail mount
Hook the front tab on the rail (or
mounting bracket) and then press the
rear section.
2. Removal
To remove the front tab, press the unit
forward, and pull the front section up.
3. Side mount
Install the side of the amplifier unit using
an optional mounting bracket.
1. To open the sensor cover
Lift the cover by pulling up the tab.
2. To remove the case cover
The cover can be removed by pressing
the edge of the fully opened cover.
3. To attach the case cover
Place the removed cover on the amplifier
unit as shown and then press the hinge.
Press
Press
Press