background image

10000229312

00

G. FILLUS

12-22-11

1

12

B

SIX SHEETS,

TWO SIDES PRINTED,

BODY STOCK WHITE,

BODY INK BLACK

FLAT

FOLDED

SIZE

MATERIAL

-20°C to +55°C (-4°F to +131°F)

8-1/2 IN. W  x 11 IN. H

 2-1/8 IN. W x 2-3/4 IN. H

OR

OR

210mm W x 297mm H

52.5mm W x 74.25mm H

UL Type 4/4X/13/3R

210mm W  x  297mm H

8 - 1/2" W  x  11" H

CUT SIZE

Disconnect from power source to prevent electrical shock before installing 

or servicing. Check power supply voltage and frequency. 

 

Déconnecter l’alimentation avant toute opération d’installation ou de maintenance, 

afin d’éviter les décharges électriques. Controler la tension et la fréquence d’alimentation. 

Scollegare dall’alimentazione prima dell’installazione e della messa in servizio. 

Controllare la tensione di alimentazione e la frequenza. 

Desligar a alimentação antes de realizar qualquer intervenção. Verificar a tensão e 

frequência da alimentação. 

Durante el proceso de instalación o mantenimiento desconectar la tensión de 

alimentación para evitar descargas eléctricas. Comprobar tensión y frecuencia de alimentación. 

Schalten Sie den Strom während der Installation oder bei Wartungsarbeiten ab um  

einen elektrischen Schlag zu vermeiden. Prüfen Sie die Spannung und Frequenz der Stromquelle. 

WARNING

AVERTISSEMENT

WARNUNG

AVVERTENZA

ATENÇÃO

ADVERTENCIA

  
 

 

 

 

Bulletin 855H Recordable Horn  

   

    (Frame E / Flare)

855H-R30E, 855H-R45E, 855H-RC30Ex, 855H-RC45Ex

IP66 - Frame E

IP66/67 - Flare

Wiring practices must meet applicable electrical codes.

Les procédures de câblage doivent répondre aux codes électriques en vigueur.

Bei der Verdrahtung sind die geltenden elektrotechnischen Sicherheitsvorschriften zu befolgen.

Le procedure adottate per i cavi devono rispettare le codifiche elettriche applicabill.

A instalação da fiação deve atender aos códigos elétricos aplicáveis.

Las prácticas de instalación eléctrica deben seguir los códigos eléctricos. 

FEATURES:






4 stages - Each stage can record up to 30 seconds of CD quality audio
Record via on-board microphone or from external source using audio input jack
Message can be played back preceded by one of forty five alarm tones, or without any alarm tone if desired
Master / Slave functionality allows multiple horns to be set up exactly the same way
Optional high-output LED beacon available
Horn / LED combination units allow user to select steady or flashing LED function (2 Hz flash rate)

OPERATING AND MARKING:

All units have the following operating requirements and limitations.

855H Horn only units:

Catalog No. 

Voltage Range

Current

855H-R30E          14-30V DC                779mA@14V

855H-R30F                                            1.51A@24V

                                                               1.85A max@30V

855H-R45E           90-260V AC              542mA@120V

855H-R45F            (50/60Hz)                 517mA@230V

                                                               668mA max@260V

855H Combined horn/LED units:

Catalog No. 

Voltage Range

Current

855H-RC30Ex     14-30V DC                936mA@14V

                                                              1.67A@24V

                                                              1.92A max@30V

855H-RC45Ex      90-260V AC             602mA@120V

                              (50/60Hz)                552mA@230V

                                                              701mA max@90V

Prior to use, the unit will need to be configured to suit the end user.

If recording either via the onboard microphone or the line-in jack, the unit will need to be supplied with power.

HORN SET-UP AND RECORDING

AC and DC units should be powered normally to complete recording and set-up.

Risk of Electrical Shock. Disconnect from power source to prevent electrical 

shock before servicing. 

WARNING

  

1

Sound Output @ 1 meter: 

111 dB (A) Voice     112 dB (A) Music    126 dB (A) Tone

              INSTRUCTION SHEET
                   FOR BUL. 855H
      RECORDABLE HORN FRAME E

855H-R30F, 855H-R45F

Hearing protection required.

 

Summary of Contents for 855H-R30E

Page 1: ...orschriften zu befolgen Le procedure adottate per i cavi devono rispettare le codifiche elettriche applicabill A instala o da fia o deve atender aos c digos el tricos aplic veis Las pr cticas de insta...

Page 2: ...ge alarm The unit can then be switched to sound second third and fourth stage alarm tones The tones are selected by operation of DIP switch S4 on the main PCB The tone selection table page 12 shows th...

Page 3: ...riate stage terminal otherwise the unit will be damaged WARNING DC CIRCUIT WIRING DIAGRAM CUSTOMER SUPPLIED SWITCHES BEACON PRE WIRED INTERNALLY TERMINALS ON PCB Beacon Sounder S4 S3 S2 S4 S3 S2 3 AC...

Page 4: ...to steady mode if desired To alter the settings change the position of the header pin as shown Remove header for steady mode Keep header in standard position for 2Hz flashing mode 4 MOUNTING DIMENSION...

Page 5: ...me Controls On board microphone Audio Line in PEAK Peak Level LED DC Power Alarm Stage Terminal Master Slave Connector Jumpers Function LEDs S2 Set up S4 Tones TONE VOLUME VOICE VOLUME MIC LINE IN 6 O...

Page 6: ...all the recorded stages and also reset the unit Once the user has configured the unit it must be put into its Playback Mode and S2 switches set to stage 1 as shown in Quick Ref Playback Mode Stage 1 i...

Page 7: ...ned to the microphone The peak detector LED should flash regularly to maintain a good recording level However if it stays on for most of the time the recording may be distorted Press action button Sto...

Page 8: ...vely for For Stage 2 Set Switch S2 positions 1 3 5 to ON For Stage 3 Set Switch S2 positions 1 2 5 to ON For Stage 4 Set Switch S2 positions 1 5 to ON 2 Switch on power or Press reset button 3a 8 Unit...

Page 9: ...t Switch S2 positions 2 3 7 to ON Alternatively For Stage 2 Set Switch S2 positions 3 7 to ON For Stage 3 Set Switch S2 positions 2 7 to ON For Stage 4 Set Switch S2 position 7 to ON 2 Switch on power...

Page 10: ...7 to ON 2 Set jumper J4 ME to ON position centre and right pin connected 3 Switch on power or Press reset button 4a Press action button Erase will begin 4b erase complete 5 Reset Jumper J4 ME to OFF...

Page 11: ...and S4 dip switches and jumper J4 ME does not affect synch operation 3 Apply power to the Master unit first Then apply power to the Slave unit Master Unit Slave Unit 4a Press action button on the Mas...

Page 12: ...1 Hz Sweeping Tone 8 500 1200 500 Hz 0 3 Hz Sweeping Tone 9 1200 500 Hz 1 Hz DIN PFEER P T A P Tone 10 2400 2900 Hz 2 Hz Alternating Tone 11 1000 Hz 1 Hz Intermittent Tone 12 800 1000 Hz 0 875 Hz Alt...

Reviews: