PRODUCT SPECIFIC SAFETY WARNINGS

> Unplug all tools to be connected with the Dust Collection 

  Grounding Kit before beginning installation.

>  If multiple machines are connected to your dust collection 

  system, it is recommended that you run a wire from each 

  machine to the ductwork junction and then connect it to 

  the wire leading to the dust collector.

>  Each piece of power equipment, including the dust 

  collector, must be properly grounded via a three-prong 

  plug for this system to be effective.

>  Each piece of wire ending at a machine must be secured 

  to bare metal on the frame of the machine. There must be 

  metal-to-metal contact for the system to function.

>  When drilling holes for grounding screws in the metal 

  frames of machines, carefully position the holes and take 

  care not to drill into any internal parts of the machines. 

  Failure to exercise care could result in damage 

  to the machines.

>  Recommended for use only with permanently 

  installed ductwork.

>  If, after reading these instructions, you are unsure that you 

  can install the grounding system properly, please contact a 

  licensed electrician.

    

Quantity

 1  Copper Wire, 50' 

1

  2  Grounding Screws 

2

  3  3/32" Drill Bit 

1

  4  Ring Terminal  

2

  5  Twist-on Wire Connectors 

5

PARTS LIST

5

1

3

2

2

4

4

Summary of Contents for Dust Right 18003

Page 1: ...structions prior to use for important safety information Always check Rockler com to confirm that you are using the most recent manual version for your product Dust Collection Grounding Kit Instructions Effective March 2019 ...

Page 2: ...rchaser of this product to ensure that any anyone you allow to use this product reads and complies with all instructions and safety precautions outlined in this manual prior to use Follow all standard shop safety practices including Keep children and bystanders away from the tool operating area Do NOT use power tools in explosive environments or in the presence of flammable liquids fumes or dust T...

Page 3: ...ng at a machine must be secured to bare metal on the frame of the machine There must be metal to metal contact for the system to function When drilling holes for grounding screws in the metal frames of machines carefully position the holes and take care not to drill into any internal parts of the machines Failure to exercise care could result in damage to the machines Recommended for use only with...

Page 4: ...for a secure connection 5 At each machine connected to the dust collection system drill and tap a hole into the tool s metal frame to accept an M5 x 0 8 Grounding Screw 2 Use an abrasive to remove paint from the machine frame around the screw hole and then attach the Ring Terminal 4 to the frame of the machine with a Grounding Screw 6 If you are joining wires from multiple machines at a junction f...

Reviews: