The Eliminator

Rotogauge Replacement

For LP Gas & NH

3

Service

Application

The Eliminator

direct-reading float gauge is a direct re place ment

for 1" NPT rotary-type gauges in LP and NH

3

storage tanks.

These gauges are de signed for larger tanks up to 84"

[2134mm] in diameter. The Elim i na tor

is not intended for use

in filling tanks - its use is re strict ed to tanks with fixed liquid level

gauges, used to determine when the maximum fill level has been

reached. The eliminator can be used in mobile ap pli ca tions up to

72" [1828mm] in diameter.

How To Do The Conversion

1.

After the storage tank has been evacuated, remove the ro ta ry gauge

from the 1" NPT open ing at the centerline of the head. Clean and re-

tap the fe male threads.

2.

Remove the two screws from the bezel. Put the bezel, 

screws and dial chamber aside for the moment. Remove the four

mount ing screws holding the gauge head to the adapt er.

3.

Insert the lower portion of the replacement gauge, including the float

bulb, float arm, gear hous ing and counterbalance, into the tank open ing.

4.

Apply three wraps of 

1

2

" [12mm] wide Te flon tape, or other suitable thread

seal ant, to the 1" NPT threads on the steel adapt er through which

the gauge support pass es.

5.

Screw the adapter into the tank open ing to achieve a  leak-tight

joint, and align the gauge mounting holes in the hor i zon tal plane.

6. 

Using the gasket and four mounting screws supplied, attach the

gauge to the adapter fingertight. Be sure the gauge is right side

up, the bracket tab for lo cat ing dial cham ber should be on the

right. Torque the mounting screws even ly to 140/150 lb.in.,

[16,4Nm] us ing a cross pat tern.

7. 

Reattach the 4" dial chamber and be zel to the Se nior

gauge head brackets using the two screws supplied.

8. 

If you end up with the dial cham ber up side down, you cannot

solve the problem by ro tat ing the brack et. You must ro tate the

en tire gauge 180°.

05/17/13

ISO 9001:2008 CERTIFIED

Any Eliminator installed in a tank greater than 44” is excluded

from the Rochester Gauge Limited Warranty.

Part #

Fits Tank

Size I.D.

Stationary

P6293-R4400

Mobile

Up Thru 44”

[1210]

Stationary

P6293-R6000

Mobile

44.1” Thru 60”

[1210] - [1524]

Stationary

P6293-R7200

60.1” Thru 72”

[1524] - [1829]

Mobile

PM6293-R7200

60” Thru 72”

[1524] - [1829]

Stationary

P6293-R8400

72.1” Thru 84”

[1829] - [2134]

P6293

Series

Th

e E

lim

in

ato

r

Ro

to

ga

ug

e R

e p

la

ce

 m

en

t

READ COMPLETELY WARNINGS & CAUTIONS BEFORE

AT TEMPT ING GAUGE REMOVAL OR IN STAL LA TION*

THESE INSTRUCTIONS ARE PRE PARED TO ASSIST TRADES MEN AND OTH ERS QUALIFIED

TO SERVICE LIQUID STORAGE TANK EQUIPMENT. CONSUMERS ARE NOT QUAL I FIED TO

PERFORM THE IN STAL LA TION DE SCRIBED BELOW. IF YOU HAVE ANY QUESTIONS CON -

CERN ING IN STAL LA TION OR OPERATION OF THE GAUGE OR GASKET, CONTACT ROCH ES -

TER  GAUGES,  INC.  OR  ONE  OF  OUR  AUTHORIZED  DIS TRIB U TORS  FOR  ASSISTANCE.

CHECK SIDE OF GAUGE HEAD FOR MODEL NUMBER AND ASK FOR GAUGE INSTALLATION

IN STRUC TIONS FOR YOUR MOD EL.