24
PROBLEM
POSSIBLE CAUSE
SOLUTION
The cleaning function stops.
The pre-set cleaning time of 2 minutes has ex-
pired.
This is normal. Activate the cleaning function
again.
The infrared sensor has stopped detecting the
user. If the position during use is too forward, the
device might stop detecting the user.
Sit down correctly. Reactivate the cleaning func-
tion.
*
Failure of power supply.
Verify the electrical system or unplug and plug in
the cable to the mains.
The cleaning function stops and the lights blink
twice every 5 seconds.
Not enough water is entering the In-Wash. The
shut-off valve is closed or there is a general su-
pply failure.
Verify there is water supply from the mains and
reset the product (See 3.6).
Not enough water is entering the In-Wash. The
water inlet filter is blocked.
Clean the water filter (See 4.1.3) and reset the
product (See 3.6).
Not enough water is entering the In-Wash. The
inlet flexible hose is pinched or bent.
Reposition the inlet flexible hose and reset the
product (See 3.6).
*
Not enough water is entering the In_Wash for no
previous reason.
*
The cleaning function stops and the lights blink
twice every 5 seconds.
The water outlets of the tip might be blocked due
to limescale or there is a blockage in the water
circuit.
Descale the tip of the nozzle and reset the pro-
duct (See 3.6).
*
The cleaning function stops and the lights blink
4 or 5 times every 5 seconds.
The water has heated up excessively.
Reset the product (See 3.6).
*
The cleaning water is not warm.
The water is adjusted to room temperature.
The water is adjusted to room temperature.
The cleaning water is not warm and the lights
blink 6 times every 5 seconds,
The water heating tank is not working.
Reset the product (See 3.6).
*
The cleaning water is not warm and the lights
blink 7 times every 5 seconds.
The temperature sensors are not working co-
rrectly.
Reset the product (See 3.6).
*
The nozzle does not move backwards.
The power supply has been cut.
Restore the power connection. The nozzle will
move backwards automatically.
The engine of the nozzle has lost its position.
Reset the product. (See 3.6).
*
The drying stops or it does not work.
The pre-set drying time of 3 minutes has expired. This is normal. Reactivate the drying function.
The infrared sensor has stopped detecting the
user. If the position during use is too forward, the
device might stop detecting the user.
Sit down correctly. Reactivate the cleaning func-
tion.
*
The temperature of the drying air is not warm
enough.
The temperature of the drying air is set to room
temperature.
Increase the temperature by means of the remote
control.
The air heater is not working.
*
The seat moves when sitting down.
The rear brackets of the seat are not tight enou-
gh.
Tighten the rear brackets of the seat.
*
Should the problem persist, please call the Technical Assistance.
6. TECHNICAL FEATURES
❚
6.1 FEATURES / SPECIFICATIONS
SPECIFICATIONS
Model
In-Wash
INSPIRA
Power supply
220-240V AC
Frequency
50/60Hz
Max. power input
1700W
Heat output
Water heater
1650 W
Hot air dryer
300 W
Temperature range
Service temperature
10ºC / 30ºC
Water temperature 4 levels
OFF / 33 / 36 / 39ºC
Temperature of the warm air dryer 4 levels
OFF / 40 / 50 / 60ºC
Storage temperature
-10ºC / 60ºC
Water pressure
0,05 Mpa / 0,9 Mpa (0,5 bar - 9 bar)
Cleaning
Flow perineal position
0,45 – 0,55 – 0,65 l/min
Flow anal position
0,65 – 0,75 – 0,85 l/min
Safety devices
Fuse and Thermostat
Drying
Air speed of the dryer
8,5 m/s
Safety device
Fuse
Length of the connecting cable
1,5 M