7
filtration button, the controller memorizes the setting and
returns to its normal work. If no button is pressed for longer
than 5 seconds during the setting procedure, the controller
will quit the filtration setting menu and will not remember
any changes.
2.7. FAST FILTRATION (BOOST)
The “boo” function enables to make faster water filtration.
During this function, all the pumps work for 1 minute. Addi-
tionally, pump 1 works in a fast gear for 45 minutes along
with the ozonator. The heater works normally during the fast
filtration process. After switching this function on, the „boo”
sign appears on the display and is present until this function
is finished. Fast filtration process is triggered by pressing and
holding the pump 1 button for 10 seconds. This function can
be switched off earlier by starting any other pumps.
2.8. SETTING THE WATER TEMPERATURE
To set the water temperature, press the arrow buttons
UP
DOWN
on the control panel.
The selected temperature does not have to be confirmed, but
only set. The display, after 5 seconds from the last pressing,
will return to the previous status and start showing the current
water temperature. The controller maintains the set tempe-
rature with an accuracy of ± 0,5°C (1°F). If the water tempe-
rature is lower than that previously set, the controller will start
the heater and low gear pump1 (filtration circuit) and keep it
on until the water reaches its required temperature. If the
economy mode is on
ECONO
the controller keeps the water
temperature lower by 10 degrees than that previously set.
After the economy mode is off, the controller returns to
maintaining the previous temperature set.
2.9. INCREASING THE MAXIMUM TEMPERATURE
This function allows the user to increase the water tempera-
ture by two degrees centigrade above 40°C (104°F). To set
the temperature above 40°C, set the maximum temperature
and next press and hold the up arrow button
UP
for
5 seconds until the Orx.x sign apears on the display, where
x.x signifies how much the temperature value is to be increa-
sed above the maximum temperature. This value can be in-
creased half a degree, and the maximum value is two grades,
so the maximum water temperature is 42° C. To return to a
normal mode of setting the water temperature, press the
down arrow button
DOWN
a few times until the normal
temperature, ranging from 15 to 40°C, appears on the dis-
play.
2.10. “STAND-BY” FUNCTION
This function blocks access to all devices connected to the
controller for 60 minutes. This function stop all functions
without need of disconnecting the power supply. To switch
on this function, press this button
FILTER
5 seconds.
After switching this function on,
the “Sby” sign will
appear together with the time left to the end of this func-
tion.
There are three methods to stop this function automaticaly:
●
Wait 60 minutes until this function stops.
●
Press this button
FILTER
for longer than 5 seconds when the
function works.
●
Disconnect the controller from the power supply.
The “Stand-By” function blocks the filtration function. If 40
minutes after going out from “Stand-By” mode SPA still will
be in filtration period, filtration mode will start again.
2.11. CONTROL PANEL KEYBOARD LOCKING
Partial keyboard locking:
●
Press and hold this button
ECONO
. During this operation, the
key-shaped icon blinks.
●
The LocP sign will appear on the display after pressing this
button on the control panel for 3 seconds. Once this sign has
appeared, the function becomes active and the key icon is
on permanently. The main and optional control panel are
locked.
●
Release the button.
●
Following keys are blocked now: jets, light air/aux and all
the keys in optional panel.
To unlock the panel, press and hold this button
ECONO
for not
less than 5 seconds.
The LocP sign will appear on the display if any button is pres-
sed after locking the keyboard. The partial keyboard locking
function is not remembered after a power cut-off.
Total keyboard locking:
●
Press and hold this button
ECONO
. The key-shaped icon blinks
during this operation.
●
The “LocP” sign will appear on the display after pressing
this button on the control panel for 3 seconds. Once this sign
has appeared, the function becomes active and the key icon
is on permanently. The main and optional control panel are
locked.
●
Keep this button pressed.
●
After 5 seconds the LocF sign appears, and since that mo-
ment the function is active.
●
Release the button.
All the buttons in both panels are locked.
To unlock the panel, press and hold this button
ECONO
for not
less than 5 seconds.
The LocF sign will appear on the display if any of the locked
buttons is pressed after locking the keyboard. The total ke-
yboard locking function is not remembered after a power
cut-off.