26
A
The electrical installation must be protected by means of a I
Δ
n 0,03A and 25A differential switch and a magnetothermal
switch of 10 or 15A. Both switches must be placed outside the bathroom.
B
The power connection of this product must be permanently connected to a fixed electricity line. Placement of a plug is not
acceptable.
C
The electrical line to be installed must be a hose consisting on two drivers (phase and neutral) of at least 1mm2 of section
exclusively dedicated to the Smart Shower.
D
It is recommended to install mixer box, WIFI/BT module and power supply in false ceiling. (Minimum distance between WIFI/
BT module and user 200mm).
25A l
D
n 0.03A
10 ó 15A
L max:
3m
C
A
B
2 x 1mm
2
L Min. = 300 mm
ØMin: 6 mm
ØMax: 8,5 mm
Included
600
2250
600
V2
V3
V1
V0
D
Recommended location
Mixer, WIFI/BT module
and power supply
V = Volume
Mandatory
According to current legislation
The mixer must be installed out of volumes V0 and V1.
The power supply and electrical connection muste be
installed out of volumes V0, V1 and V2.
These recommendations are valid as long as the
installation is compatible with the country regulations.
English