GB
18
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too little
oil in the engine. In this case it will not be possible to
start the engine or it will cut out automatically after a
short period of time. It cannot be started again until
the engine oil has been topped up (see point 7.4).
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
9. Troubleshooting
Fault
Cause
Remedy
Engine does not start
Automatic oil cut-out has not
responded
Spark plug fouled
No fuel
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / have the petrol cock
checked
Generator has too little or no
voltage
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air filter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
Anleitung_RB_PG_5500_2_SPK7__ 15.01.15 09:25 Seite 18
Summary of Contents for 41.525.01
Page 4: ...4 10 11 14 13 12 8 D 9 7 B C A A E Anleitung_RB_PG_5500_2_SPK7__ 15 01 15 09 25 Seite 4 ...
Page 5: ...5 15 1 2 3 4 Anleitung_RB_PG_5500_2_SPK7__ 15 01 15 09 25 Seite 5 ...
Page 34: ...34 Anleitung_RB_PG_5500_2_SPK7__ 15 01 15 09 25 Seite 34 ...
Page 35: ...35 Anleitung_RB_PG_5500_2_SPK7__ 15 01 15 09 25 Seite 35 ...
Page 40: ...40 EH 01 2015 01 Anleitung_RB_PG_5500_2_SPK7__ 15 01 15 09 25 Seite 40 ...