2. Layout and items supplied
2.1 Layout (Fig. 1-4)
1. Intake
air
fi
lter
2. Pressure
tank
3. Wheel (axle mounted)
4. Foot
5. Quick-lock coupling (regulated compressed
air)
6. Pressure gauge (for reading the set pressure)
7. Pressure
regulator
8. On/O
ff
switch
9. Transport
handle
10. Safety valve
11. Drainage screw for condensation water
12. Pressure gauge (for reading the vessel pres-
sure)
13. Quick-lock coupling (unregulated com-
pressed air)
14. Oil sealing plug
15. Oil drainage screw
16. Oil level window
17. Oil
fi
ller opening
18. Washer (small)
19. Axle screw
20. Spring washer
21. Nut for
fi
tting the axle
2.2 Items supplied
Please check that the article is complete as
speci
fi
ed in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
instructions.
•
Open the packaging and take out the equip-
ment with care.
•
Remove the packaging material and any
packaging and/or transportation braces (if
available).
•
Check to see if all items are supplied.
•
Inspect the equipment and accessories for
transport damage.
•
If possible, please keep the packaging until
the end of the guarantee period.
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or su
ff
ocating!
•
Intake air filter
•
Wheel (axle pre-mounted) (2x)
•
Foot
•
Oil sealing plug
•
Washer, small (6x)
•
Spring washer (2x)
•
Nut for fitting the axle (4x)
•
Original operating instructions
3. Proper use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: .......................... 110 V ~ 60 Hz
Motor rating: ..............................2.2 HP S2 15 min
Speed (motor) min
-1
: .................................... 3450
Speed (pump) min
-1
: .................................... 3450
Operating pressure psi: ..........................max. 116
Pressure vessel capacity (in liters): ................. 50
Theoretical suction rate l/min ........................ 230
Output (compressed air) at 102 psi: .
........................................................ 100 liters/min
Output (compressed air) at 58 psi: .. 118 liters/min
Sound power level L
WA
in dB: ............................ 97
K
WA
uncertainty: .............................................3 dB
Sound pressure level L
pA
in dB: ....................... 85
K
pA
uncertainty: .............................................3 dB
Protection type: ............................................. IP20