Transport and positioning
18
2
k18 Simplygas C1
Degree of protection
IP
-
25
Installation data
Gas consumption
G20 natural gas (nominal)
m³/h
1,20 (4)
LPG G30/G31 (nominal)
kg/h
0,87 (5)
Water fitting
type
-
M
thread
“
3/4
Gas connection
type
-
M
thread
“
1/2 (6)
Flue gas exhaust
diameter (Ø)
mm
80
residual head
Pa
70
type of installation
-
B23P, B53P
NO
x
emission class
-
5
Dimensions
width
mm
1145
depth
mm
721 (7)
height
mm
1333
Weight
in operation
kg
215
sound pressure L
p
at 5 metres (max)
dB(A)
43,0 (8)
sound pressure L
p
at 5 metres (min)
dB(A)
40,0 (8)
maximum water pressure in operation
bar
4,0
maximum condensation and defrosting water flow rate
l/h
13,5
Water content inside the apparatus
l
1
required air flow
m³/h
4000
Circulating pump data
maximum head
m w.c.
8,0
residual pressure head at nominal flow rate
m w.c.
4,0
nominal flow at the maximum available head
l/h
1500
maximum electrical consumption
W
75
General information
Cooling fluid
ammonia R717
kg
4,3
water H
2
O
kg
4,4
(1)
Relative to NCV (net calorific value).
(2)
In transient operation, lower temperatures are allowed.
(3)
10 minute peak collection of domestic hot water. The exact value depends on the performance of the DHW buffer tank.
(4)
PCI (G20) 34,02 MJ/m³ (15 °C - 1013 mbar).
(5)
PCI (G30/G31) 46,34 MJ/kg (15 °C - 1013 mbar).
(6)
It is possible to reduce gas pipe diameter to 3/8”, ensuring enough gas pressure to the appliance, considering pressure losses of entire gas supply pipe.
(7)
Dimensions including flue gas discharge.
(8)
Sound pressure values in free field, with directionality factor 2, obtained from the sound power value in compliance with standard EN ISO 9614. Sound power Lw 65 dB(A) at maximum
ventilation, 62 dB(A) at minimum ventilation; sound power values detected in compliance with the intensity measurement methodology set forth by standard EN ISO 9614.
Table 1.3
K18 Simplygas PED data
k18 Simplygas C1
PED data
Components under pression
generator
l
14,5
cooling volume transformer
l
3,0
absorber/condenser
l
2,2
cooling absorber solution
l
4,2
solution pump
l
2,8
test pressure (in air)
bar g
55
maximum pressure of the cooling circuit
bar g
32
filling ratio
kg of NH
3
/l
0,161
fluid group
-
group 1°
2
TRANSPORT AND POSITIONING
2.1
WARNINGS
Damage from transport or installation
The manufacturer shall not be liable for any damage dur-
ing appliance transport and installation.
On-site inspection
Upon arrival at the site, ensure there is no transport
damage on packing, metal panels or finned coil.
After removing the packing materials, ensure the appli-
ance is intact and complete.
Packing
Only remove the packing after placing the appliance on
site.
Do not leave parts of the packing within the reach of
children (plastic, polystyrene, nails...) since they are po-
tentially dangerous.