APPENDICES
PRODUCT FICHE
Figure
Model(s):
K18 Hybrigas
Air-to-water heat pump:
yes
Water-to-water heat pump:
no
Brine-to-water heat pump:
no
Low-temperature heat pump:
no
Equipped with a supplementary heater:
yes
Heat pump combination heater:
no
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
33,3
kW
Seasonal space heating
energy efficiency
η
s
126
%
Tj = -3 °C
Pdh
24,3
kW
Tj = -3 °C
PERd
111
%
Tj = +1 °C
Pdh
19,3
kW
Tj = +1 °C
PERd
127
%
Tj = +4 °C
Pdh
15,3
kW
Tj = +4 °C
PERd
140
%
Tj = +8 °C
Pdh
10,3
kW
Tj = +8 °C
PERd
141
%
Tj = +12 °C
Pdh
5,0
kW
Tj = +12 °C
PERd
143
%
Annual energy consumption
Q
HE
197
GJ
Rated heat output (*)
Prated
32,4
kW
Seasonal space heating
energy efficiency
η
s
120
%
Tj = -12 °C
Pdh
24,0
kW
Tj = -12 °C
PERd
97
%
Tj = -7 °C
Pdh
19,8
kW
Tj = -7 °C
PERd
113
%
Tj = -1 °C
Pdh
14,6
kW
Tj = -1 °C
PERd
127
%
Tj = +5 °C
Pdh
9,4
kW
Tj = +5 °C
PERd
141
%
Tj = +10 °C
Pdh
5,2
kW
Tj = +10 °C
PERd
143
%
T
j
= operation limit
temperature
Pdh
32,4
kW
Tj = operation limit
temperature
PERd
92
%
For air-to-water heat pumps:
T
j
= –15 °C (if TOL < –20 °C)
Pdh
26,6
kW
For air-to-water heat pumps:
Tj = –15 °C (if TOL < –20 °C)
PERd
95
%
Annual energy consumption
Q
HE
240
GJ
Rated heat output (*)
Prated
37,2
kW
Seasonal space heating
energy efficiency
η
s
131
%
Tj = +6 °C
Pdh
26,4
kW
Tj = +6 °C
PERd
120
%
Tj = +8 °C
Pdh
21,2
kW
Tj = +8 °C
PERd
136
%
Tj = +10 °C
Pdh
16,0
kW
Tj = +10 °C
PERd
140
%
Tj = +12 °C
Pdh
10,8
kW
Tj = +12 °C
PERd
141
%
Tj = +14 °C
Pdh
5,2
kW
Tj = +14 °C
PERd
143
%
Annual energy consumption
Q
HE
137
GJ
Table 8
COMMISSION DELEGATED REGULATION (EU) No 811/2013
Parameters shall be declared for average, colder and warmer climate conditions.
Technical parameters for heat pump space heaters and heat pump combination heaters
Parameters shall be declared for medium-temperature application.
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or primary energy
ratio for part load at indoor temperature 20 °C and
outdoor temperature Tj
AVERAGE CLIMATE CONDITIONS
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or primary energy
ratio for part load at indoor temperature 20 °C and
outdoor temperature Tj
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or primary energy
ratio for part load at indoor temperature 20 °C and
outdoor temperature Tj
COLDER CLIMATE CONDITIONS
WARMER CLIMATE CONDITIONS