Maintenance
Installation, use and maintenance manual – Calorio M
29
7
Table 7.1
Faults
Fault
Code
ACTION
Lock-out due to ignition failure
01
Manual reset
Lock-out due to temperature limit function trip
02
Manual reset
Lock-out due to generic internal error
03
Manual reset
Air pressure switch/blower fault
05
TAC intervention
Room probe fault
06
TAC intervention
Prelimit probe fault
07
TAC intervention
Gas-fired convector body overheating
10
Automatic reset
Lock-out due to parasitic flame
11
Automatic reset
Lock-out due to valve drive hardware fault
20
Automatic reset
Lock-out due to valve control relay fault
21
Automatic reset
Flame lock-out after valve shut off
22
Manual reset
Lock-out caused by wiring faults
23
Manual reset
Lock-out due to 3 or more ignition attempt failures
91
Manual reset (1)
Mains frequency synchronism error
96
TAC intervention
Low supply voltage
97
TAC intervention
Lack of communication between main board and user interface
NCOM
TAC intervention
1
Resettable after waiting 1 hour or power cycling the appliance.