VENTBOSS
•
SERIES 300 SPACE SAVER COLLECTORS OWNER’S MANUAL
29
APPENDIX A:
INSTALLATION, OPERATION & MAINTENANCE
(continued)
Maintenance & Repair
In order to obtain appropriate capture efficiency of the suction hood, clean its surface
and the inlet wire-mesh net from the deposited dusts and impurities. In case of welding
dusts, additionally – sprinkle the hood with an anti-spattering liquid to avoid adhesing
the welding chippings.
In case when the extraction arm is losing its self-supporting properties – undertake the
adjustment of its frictional brakes (to regain self-locking function of the joints).
Lubricate the swivel every 3 months using solid grease (lubrication nipple is located in
the swivel flange).
After 1 operational year, submit the device to a technical revision and repair or replace the
faulty element.
Clean the internal surfaces of the extraction conduits (segment pipes) from the deposited
impurities. Revision frequency depends on the operational intensity. It is recommended to
examine the pollution state of the discharge conduits once in three months.
Transportation & Storage
VentBoss extraction arms have to be stored and transported in partly disassembled state and
in special packages. The devices ought to be stored in dry and well ventilated rooms. During
the transport / reloading protect the device from scratching, indents and pay attention that
the markings and labels would not get detached/obliterated.
Warranty
The period of warranty for the purchased device is indicated in the “Card of Warranty”. The
warranty does not comprise:
• defects and damages arising during the incorrect use and in application that is
inconsistent with the present manual
• mechanical and electrical damages being caused during improper storage and transport
or incorrect mainte nance
• structural modifications, or changes / adaptations introduced by User on one’s own
• inefficiency following from the normal operational exhaustion
Infringement of the section 3 “
Reservations of producer
” of the
Owner’s Manual
and especially modifications undertaken by User on one’s own shall cause the loss of
warranty validity.