![RoboteQ CANBus Series User'S Reference Manual Download Page 52](http://html1.mh-extra.com/html/roboteq/canbus-series/canbus-series_users-reference-manual_1471291052.webp)
CAN Networking on Roboteq Controllers
52
CANBus Networking Manual
V2.0 July 8, 2019
0x6046 - VL Velocity Min Max Amount
Table 4-23 gives a short description of the object.
TABLE 4-23. Velocity Min Max Amount
Sub-Index
01
Optional N Type U32 Access
RW
PDO
R
Value Range
Default
0
RoboCommand
SPL
Description
VL velocity min amount.
Sub-Index
02
Optional N Type U32 Access
RW
PDO
R
Value Range
Default
1000
RoboCommand
SPL
Description
VL velocity max amount.
Figure 4-3. Velocity Min Max Amount
This object shall indicate the configured minimum and maximum amount of velocity in
RPM. The vl velocity max amount sub-object shall be mapped internally to the vl velocity
max positive and vl velocity max negative values. The vl velocity min amount sub-object
shall be mapped internally to the vl velocity min positive and vl velocity min negative val-
ues. as shown Figure 4-3.
0x6048 - VL Velocity Acceleration
Table 4-24 gives a short description of the object.
TABLE 4-24. Velocity Acceleration
Sub-Index
01
Optional N
Type U32
Access
RW
PDO
R
Value Range
Default
MAC(20000)
RoboCommand
SAC
Description
Delta speed in RPM*10.
Sub-Index
02
Optional N
Type U16
Access
RW
PDO
R
Value Range
Default
1
RoboCommand
SAC
Description
Delta time in seconds.