12
TROUBLE SHOOTING
• THE POWER MIXER DOES NOT START.
1. Did you follow the previous operating instructions
?
(See section-Operating The Power Mixer).
2. Is the machine too hot
?
Allow the power mixer
to cool. Then retry.
3. Pull the plug and try another outlet.
4. Check the GFI trip indicator on your outlet.
Check the circuit breaker.
5. Call local Robot Coupe authorized service
agency.
• THE POWER MIXER STOPS DURING (WHILE)
PROCESSING.
See the section On Operating the Power Mixer.
- The first paragraph describes the overload protection.
It may be necessary to allow the machine to cool
for up to 30 minutes before restarting.
If you cannot locate the cause of the problem
- Release the control button (CB).
- Unplug the power mixer.
- Are the blades free to rotate in the bell
?
- Is the drive shaft free to rotate
?
To check this,
unplug the power mixer, remove the bell and test the
rotation of the end of the drive shaft manually.
Check the condition of the plug and the power cord.
• THE POWER MIXER STARTS TO SMELL HOT
OR SMOKE
- Turn the power mixer off and unplug it.
- Call your local authorized service agency.
• THE MACHINE TRIPS THE GFI (Ground fault
Interrupt) OUTLET
The motor or controls are wet or damaged. Do not
attempt to use the mixer until it has been repaired
by qualified service persons.
• OVERLOAD WARNING LIGHT
(MP 600 Turbo and MP 800 Turbo)
In case of overload or
use of the mixer in a too
sticky preparation, the
intensity warning flashes
for 5 seconds to inform
you that the motor will
stop shortly. This stop
indicates that the prepa-
ration in process is too
thick or can not be made
with a stick blender.
In this case, you can still restart your mixer.
However, your machine will stop again if the
consistency of the preparation is not modified.
SERVICE
See warranty first then;
Should your unit require service, check with your
distributor to see where local service is available.
If not or if you wish your unit to be serviced at the
factory, call for return instructions and ship the unit
prepaid to our factory address.
PH : 1-800-824-1646
Robot-Coupe USA, Inc
Service Department Repair
264 South Perkins Street
Ridgeland, MS 39157
For service in Canada contact the Robot-Coupe
USA factory for repair instructions.
FLASH
W A R N I N G
• THE BLADES ARE SHARP! It is recommended
that cutting gloves be worn when handling
the blades. Handle and store the blades with
safety in mind.
• Never try to defeat the safety mechanisms!
• Never put anything (utensils etc.) but food
material near the blades on the power
mixer!
• Never overload the power mixer!
• Never turn the power mixer on unless the
bell is completely immersed in the product.
• Always unplug the power mixer before
doing any cleaning or maintenance!
Summary of Contents for MP 800 Turbo
Page 4: ......
Page 35: ...33 TECHNICAL DATA DATOS T CNICOS DONN ES TECHNIQUES...
Page 36: ...34...
Page 37: ...35...
Page 38: ...36...
Page 39: ...37...
Page 40: ...38...
Page 41: ...39...
Page 42: ...40...
Page 43: ...41...
Page 44: ...42...
Page 45: ...43...