ENG
FAULT INFORMATION
110
Code
Problem
Cause
Solution
E60
Product infeed photocell
alarm
The photocell detects that the
product is not in the correct
position or that the reflector is
not properly aligned.
Remove the product or align
the photocell with the
reflector.
E61
Product outfeed photocell
alarm
The photocell detects that the
product is not in the correct
position or that the reflector is
not properly aligned.
Remove the product or align
the photocell with the
reflector.
E62
“Clamp forward” alarm
Clamp cylinder magnetic
sensors not properly working.
Check and replace the sensor
if necessary.
E64
“Film breakage” alarm
The film has broken or spool is
finished.
Insert the film or replace
spool.
E80
“Start Pedal” alarm
Start pedal fault.
Contact
the
assistance
service.
E90
“Battery”
alarm
Flat PC battery.
Contact
the
assistance
service.