tm2605 Jan-20
5
1.4. Power requirements
ELECTRIC SOCKET MUST HAVE GROUNDING CONTACT!
CONNECTIONS MUST BE DONE ONLY BY QUALIFIED ELECTRICIAN!
IF SUPPLY CORD DAMAGED, IT MUST BE REPLACED BY MANUFACTURER,
SERVICE AGENT, OR QUALIFIED PERSONS IN ORDER TO AVOID HAZARD!
It is necessary to periodically check electric connections, including grounding
connection. Whenever any fault conditions are found, do not turn the equipment
on, and call for qualified electrician!
Equipotential bonding wire (up to 10 sq.mm) shall be connected to screw
terminal marked with IEC 5021 sign.
Cable plug is not included in the delivery set. Use a 32 A plug. Refer to
the wiring diagram on the power cord label.
It is necessary to check electric wires and ground connection of the machine
periodically. In case of faults found, an electrician must be called. It is allowed to
turn the machine on only after all the issues are resolved.
1.5. Safety components
The machine can be turned off in any time with the main switch on the front
panel.
There is an emergency temperature regulator located in heating elements area.
In case of excessive or uncontrolled heating it will cut off power supply to the
heaters.
1.6. Ambient conditions
The equipme
nt must be operated at the ambient temperature from +5° to +40°C
and relative humidity not more than 45% at 40°C. The temperature decreasing
related to RH increasing, for example, 90% of RH at 20°C. Altitude above sea
level should not exceed 1000 m. Ingress protection rating IP22 (IEC 60529).
During the operation, machine emits a lot of steam and heat. It is essential to
provide exhausting hood (800x800 mm, 1000 cu.m/hr or more) installed over
the kettle.
Ambient conditions have strong impact on the end product quality. See section