1.4. Power Requirements
CONNECTIONS MUST BE DONE ONLY BY QUALIFIED ELECTRICIAN!
ELECTRIC SOCKET MUST HAVE GROUNDING TERMINAL!
IF SUPPLY CORD DAMAGED, IT MUST BE REPLACED BY MANUFACTURER, SERVICE AGENT, OR
QUALIFIED PERSONS IN ORDER TO AVOID HAZARD!
It is necessary to periodically check electric connections, including grounding
connection. Whenever any fault conditions are found, do not turn the equipment
and call for qualified electrician!
Equipotential bonding wire (up to 10 sq.mm) shall be connected to screw
terminal marked with IEC 5021 sign.
Cable plug is not included in the delivery set. Use a 32 A plug. Refer to the
wiring diagram on the power cord label.
It is necessary to check electric wires and ground connection of the machine
periodically. In case of faults found, an electrician must be called. It is allowed to
turn the machine on only after all the issues are resolved.
1.5. Ambient Conditions
The equipment must be operated at the ambient temperature between
+5° and
+40°C (+41°F to +104°F), relative humidity not more than 45% at 40°C/104°F).
Altitude above sea level should not exceed 1000 m.
While in operation, a lot of moisture and heat is coming out of the popper. It is
essential to provide exhausting hood (800x800 mm, 750 cu.m/hr or more)
installed above popper’s output port.
Ambient conditions have strong effect on the end product quality! See
section 2.7 for more details!
1.6. Safety Components
EMERGENCY STOP button located on the back side of the machine should be
used in case of emergency, pressing the button turns machine off immediately.
USING EMERGENCY STOP BUTTON MAY LEAD TO CHAMBER CLOGGING!